Top Front Fan OK Spinning at intermediate-speed
Bottom Front Fan OK Spinning at intermediate-speed
lists the output fields for the
show chassis environment
command. The table lists
output fields in the approximate order in which they appear.
Table 38:
show chassis environment
Output Fields
Field Name
Field Description
Class
Information about the category or class of chassis component:
•
Temp
: Temperature of air flowing through the chassis in degrees Celsius (°C) and
degrees Fahrenheit (°F)
•
Fans
: Information about the status of fans and blowers
Item
Information about the chassis components:
•
Flexible PIC Concentrators (FPCs)—that is, the line cards
•
Control Boards (CBs)
•
Routing Engines
•
Power entry modules (PEMs)—that is, the power supplies
Status
Status of the specified chassis component. For example, if
Class
is
Fans
, the fan status
can be:
•
OK
: The fans are operational.
•
Testing
: The fans are being tested during initial power-on.
•
Failed
: The fans have failed or the fans are not spinning.
•
Absent
: The fan tray is not installed.
Measurement
Depends on the Class. For example, if
Class
is
Temp
, indicates the temperature in degrees
Celsius (°C) and degrees Fahrenheit (°F). If the
Class
is
Fans
, indicates actual fan RPM.
152