Problem
Description
The power system is not functioning normally.
Cause
Solution
• Check the LEDs on each power supply faceplate.
• If an AC power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs
light steadily, and the PS FAIL LED is not lit.
• If a DC power supply is correctly installed and functioning normally, the PWR OK, BRKR ON, and
INPUT OK LEDs glow steady green.
• Issue the CLI
show chassis environment pem
command to check the status of installed power supplies. As
shown in the sample output, the value
Online
in the rows labeled
State
must indicate that each of the
power supplies is functioning normally.
The output for EX9251 switches is similar to the following:
user@switch> show chassis environment pem
PEM 0 status:
State Online
Airflow Front to Back
Temperature OK 21 degrees C / 69 degrees F
Temperature OK 13 degrees C / 55 degrees F
Fan Sensor 4200 RPM
DC Output Voltage(V) Current(A) Power(W) Load(%)
12.00 8 96 3
PEM 1 status:
State Online
Airflow Front to Back
Temperature OK 19 degrees C / 66 degrees F
Temperature OK 15 degrees C / 59 degrees F
Fan Sensor 4260 RPM
DC Output Voltage(V) Current(A) Power(W) Load(%)
12.06 7 84 2
148