Maintaining the Advanced Clocking Module
51
CHAPTER 8: Maintaining the Gateway
**************************************
Input clock Priority Validity
**************************************
line-tdm-primary 2 Invalid
line-tdm-secondary 3 Invalid
ces-rec-clock 4 Invalid
ethernet-rec-clock 5 Invalid
bits-clock 6 Valid
ext-10mhz 7 Invalid
z
Use the
show output-clocks-status
command to display the status of the internal and external
output clocks for the advanced clocking module.
cli@BX7000>
show output-clocks-status
Internal output clocks:
Ethrnet clock : enable
8 Khz Sync : enable
19.44 Diff clock : enable
T1/E1 TDM Clock : enable
External output clocks:
one-pps-clock : enable
z
Use the
show pll-status
command to display the PLL status, current clock source, and the
priorities set for each clock source.
cli@BX7000>
show pll-status
PLL Status: Phase Locked
Currently Selected Source: bits-clock
First Priority Validated Source: bits-clock
Second Priority Validated Source: none
Third Priority Validated Source: none
z
Use the
show clock-card-status
command to check the status of the input and output clocks. As
shown in the sample output, the value corresponding to
priority
field indicates the priority set for
the input clock, the
validity
field indicates the status of the clock that is valid, and the
interface
field indicates the interface from which the clock source is derived.
cli@BX7000>
show clock-card-status
Input Clock Status:
*******************************************************************
Input clock Priority Validity Clock-type Interface
*******************************************************************
line-tdm-primary 2 Invalid wired t1-0/0/1
line-tdm-secondary 3 Invalid wired t1-0/0/2
ces-rec-clock 4 Invalid wired t1-0/0/3
ethernet-rec-clock 5 Invalid wired ge-1/0/1
bits-clock 6 Valid wired
ext-10mhz 7 Invalid wired
*******************************************************************
Revertive Mode : Disabled
Locked Status : Phase Locked
Clock Accuracy : 56149478475624359137401121013760.000000 PPM
Currently Selected Source : bits-clock
Highest Priority Validated Source : bits-clock
Summary of Contents for BX7000
Page 10: ... x Copyright 2010 Juniper Networks Inc ...
Page 12: ... xii Copyright 2010 Juniper Networks Inc ...
Page 18: ...About This Guide xviii Requesting Support Copyright 2010 Juniper Networks Inc ...
Page 20: ... 2 Copyright 2010 Juniper Networks Inc ...
Page 66: ... 48 Copyright 2010 Juniper Networks Inc ...
Page 90: ... 72 Copyright 2010 Juniper Networks Inc ...
Page 122: ... 104 Hardware Compliance Copyright 2010 Juniper Networks Inc ...
Page 131: ...Copyright 2010 Juniper Networks Inc 113 Appendix E Declaration of Conformity ...
Page 132: ... 114 Copyright 2010 Juniper Networks Inc ...
Page 133: ...Copyright 2011 Juniper Networks Inc 115 PART 4 Index z Index on page 117 ...