![Juniper BT8A78CH1 Hardware Overview And Installation Manual Download Page 218](http://html1.mh-extra.com/html/juniper/bt8a78ch1/bt8a78ch1_hardware-overview-and-installation-manual_2032455218.webp)
Table 89: Optical Protection Switch (OPS) FIT Rates and MTBF
MTBF
FIT Rate
(40C/90%)
PEC
Product
Years
Hours
512
4.49x10
6
223
BT7A39AB
OPS 1+1 module pluggable
260
2.28x10
6
439
BT7A39AC
OPS system control card
CAP Telco Alarm Connector Pin Assignments
Table 90: CAP Telco Alarm Connector Pin Assignments
Input Voltage Limits
Description
Pin
Maximum
Minimum
70 volts
5 volts
Minor Reset +
1
70 volts
5 volts
Minor Reset -
2
70 volts
5 volts
Major Reset +
3
70 volts
5 volts
Major Reset -
4
Output
Critical Alarm NO
5
Output
Critical Alarm NC
6
Output
Critical Alarm COM
7
Output
Minor Alarm NO
8
Output
Minor Alarm NC
9
Output
Minor Alarm COM
10
Output
Major Alarm NO
11
Output
Major Alarm NC
12
Output
Major Alarm COM
13
Output
Power NO
14
Output
Power COM
15
Copyright © 2019, Juniper Networks, Inc.
218
BTI7800 Series Hardware Overview and Installation Guide
Summary of Contents for BT8A78CH1
Page 20: ...Copyright 2019 Juniper Networks Inc xx BTI7800 Series Hardware Overview and Installation Guide...
Page 68: ...Copyright 2019 Juniper Networks Inc 68 BTI7800 Series Hardware Overview and Installation Guide...
Page 74: ...Copyright 2019 Juniper Networks Inc 74 BTI7800 Series Hardware Overview and Installation Guide...
Page 99: ...99 Copyright 2019 Juniper Networks Inc Chapter 4 Installing the BTI7800 Series Chassis...