Table 76: 400G Coherent MSA XCVR (2 X 200-Gbps) on UFM6 (continued)
Units
Maximum
Typical
Minimum
Parameter
dB
–
–
3
PDL tolerance
ps/nm
30000
–
-30000
16-QAM
Dispersion
tolerance
ps/nm
70000
–
-70000
QPSK
dB
–
–
27
Optical return loss from receiver
Other
W
125
115
–
Power Consumption
LC/UPC
Connector
Installation Rules for the 100G Coherent CFP
The following rules must be followed when installing the 100G Coherent CFP (BP3AMCTL,
CFP-100GBASE-CHRT) in a BTI7814 chassis.
Table 77: Installation Rules for the 100G Coherent CFP in a BTI7814 Chassis
Description
Rule
The 100G Coherent CFP must be installed in a BIC in BIC slot
2 of the UFM (lower slot of the UFM when viewed vertically).
Placement within the UFM
The UFM with the 100G Coherent CFP must be installed to the
immediate right of a fully occupied slot, or in slot 1 (leftmost
slot) of the chassis. A fully occupied slot is a slot that contains
a module. If that module is a UFM, then that UFM must have
BIC modules in all of its BIC slots.
Placement within the chassis
NOTE:
Failure to comply with these rules might lead to adverse thermal
behavior and premature failure.
Cleaning Transceivers
When cleaning transceivers, use an industry standard fiber optic cleaner or a 1.25 mm
cotton-tipped swab to insert into the receptacle. The swabs can be used to clean the
optical surface and to clean debris from the inner sleeve. Use extreme care as it is easy
to scratch the optical plane.
177
Copyright © 2019, Juniper Networks, Inc.
Chapter 6: BTI7800 Series Transceiver Specifications
Summary of Contents for BT8A78CH1
Page 20: ...Copyright 2019 Juniper Networks Inc xx BTI7800 Series Hardware Overview and Installation Guide...
Page 68: ...Copyright 2019 Juniper Networks Inc 68 BTI7800 Series Hardware Overview and Installation Guide...
Page 74: ...Copyright 2019 Juniper Networks Inc 74 BTI7800 Series Hardware Overview and Installation Guide...
Page 99: ...99 Copyright 2019 Juniper Networks Inc Chapter 4 Installing the BTI7800 Series Chassis...