External Clocking Port Connector Specifications
The external clocking port on the router contains four SMB connectors that support 10 MHz GPS and 1
pulse-per-second (PPS) signals. These signals can also be accessed through the External Clocking Input
port. These signals are internally isolated and have surge protection. Use a Molex 50-ohm SMB connector
or equivalent (not provided) to connect to the external clocking ports.
External Clocking Input Port Specifications
An external clocking input port labeled EXT REF CLK IN on the front panel of the router allows you to
connect external clock signal sources.
The port uses an autosensing RJ-48 connector to support framed T1 or E1 signals. Two LEDs indicate link
activity on the port and function in the same way as the T1/E1 ports. The clocking information is extracted
from the input, but the data is discarded.
provides the pinout information for the RJ-48 connector for the external clocking
input port.
Table 32: External Clocking Input Port Connector Pinouts
Direction
Description
Pin
Input
EXT_CLKA_RRING_LINE
1
Input
EXT_CLKA_RTIP_LINE
2
–
Reserved
3
Output
EXT_CLKA_TRING_LINE
4
Output
EXT_CLKA_TTIP_LINE
5
–
Reserved
6
–
Reserved
7
–
Reserved
8
SEE ALSO
Clocking Ports on the ACX2000 and the ACX2100 Router | 56
ACX2000 and ACX2100 Universal Metro Router Overview | 17
90
Summary of Contents for ACX2000
Page 1: ...ACX2000 and ACX2100 Universal Metro Router Hardware Guide Published 2020 09 07 ...
Page 91: ...Front Panel of an ACX2000 Router 47 LEDs on ACX2000 and ACX2100 Routers 57 91 ...
Page 116: ...4 CHAPTER Maintaining Components Maintaining ACX2000 and ACX2100 Components 117 ...
Page 125: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX2000 and ACX2100 126 ...
Page 139: ...139 ...
Page 144: ...Restricted Access Warning 144 ...
Page 148: ...148 ...
Page 161: ...Jewelry Removal Warning 161 ...
Page 164: ...Operating Temperature Warning 164 ...
Page 174: ...DC Power Disconnection Warning 174 ...
Page 178: ...DC Power Wiring Sequence Warning 178 ...