Operation
21/30
4156 EN
Charging voltage V/C
2,0 V/Z
Charging voltage
80 V
Charging current
35 A
Charging current %
100 %
Recharged Ah
110 Ah
Figure 6: Standard reading display during charging
6.5
Interrupting a charge
The charger should not be interrupted during charging. However, external influences
may necessitate interruption of the process. Note however:
F
F
F
F
Explosion hazard
Risk of serious damage to persons and property if the battery is disconnected during
charging. The sparks produced could ignite gases which form during charging.
Always press the ‘S’ key first, if you have to interrupt the charge.
Then disconnect the charging lead from the battery.
Charging is interrupted when you press the ‘S’ key at the front of the panel (see also
Section 6.1.2).
•
Press the ‘S’ key once. The charging status light goes out.
Charging is continued when you press the ‘S’ key again.
•
Press the ‘S’ key again. The charging status light is lit yellow or orange, depending
on the charge status.
Z
Z
Z
Z
Note
In normal operation, charging should not end before the automatic cutout. Premature
cutout will result in a depletion charge. This reduces the available battery capacity.
6.6
Charging automatic end
Charging automatically ends when the charging program is finished, i.e. the battery is
fully charged. The charge status light is then lit green. You can now use the battery. The
graphic display now shows “Charge over”, alternating with the charge end voltage data
(battery voltage in volts/cell), current (charge end current in A) and overall Ah (charged
capacity in Ah).