Operation
17/30
4156 EN
6.1.4
Adjustable parameters
Settings can be made and parameter values changed within the menu. An overview of
the various setting ranges and default values is given in the following table:
Menu item
Default value
Setting range
Language
German
German
English
French
Italian
others*
Time
00:00
00:00 - 23:59
Date
01.01.2000
01.01.2000 - 31.12.2099
Lightning intesity
70 %
0 - 100 %
Contrast
100 %
0 - 100 %
Switch-on delay
0 Min.
0 - 999 Min.
Battery service
--
Deep discharge-start
Equalisation once
Equalisation perman.
No. of measured values
5
1 – 5
1. Measured value ..
5. Measured value
Charging voltage
Charging voltage [V]
Charging current
Charging current [A]
Charging voltage [V/Z]
Charging voltage [V/Z]
Charging current [%]
Charging current [%]
Charged Ah
Charged Ah [Ah]
Battery temperature [°C]
Charging time [h]
Date
Time
Status of modules
* * Indication only if an additional language has been loaded
Table 5: einstellbare Parameter
6.1.5
Function – Battery Maintenance
Deep discharge-start:
If the message “Check battery voltage" appears in the graphic display after the battery is
connected, this means the battery voltage is insufficient to start charging. In this case a
depletion start can be performed. Select the Deep discharge start function in menu item
Functions>Battery service and confirm with OK. The charger starts in deep discharge
start mode and charges until there is sufficient battery voltage to start normal charging.
M
M
M
M
Attention
Before activating depletion start, check that the charger is preset for the battery to be charged (voltage,
capacity, type).