background image

eNet radio transmitter modules

Degree of protection

IP20

Transmitting range in free field

typ. 100 m

Radio frequency

868.0 ... 868.6 MHz

Transmission capacity

max. 20 mW

Receiver category

2

9

Parameter list

The device parameters can be changed with the eNet Server.

Device configuration

Parameters

Setting options 
Basic setting

Explanations

Function

Rocker
Other modes
Unused
Basic setting: Rocker

Rocker
The channel works as a channel button. Set-
ting is always made in pairs.
Other modes
The channel works as a scene button. Setting
is always made in pairs.
Unused
The channel is not displayed in the eNet
SMART HOME app and is disabled for use in
the commissioning interface.

Operating mode

App use, lock-out protec-
tion, forced operation, wind
alarm, sun protection, twi-
light
Basic setting: App use

Setting the type of scene used for a scene but-
ton. Setting is always made in pairs.

Advanced device settings

Parameters

Setting options 
Basic setting

Explanations

Manual commis-
sioning

On, Off
Basic setting: On

Disables manual commissioning for all device
channels. Note: In the "Off" setting, the device
cannot be reset to the factory setting.

Extended channel settings

Parameters

Setting options 
Basic setting

Explanations

Manual commis-
sioning

On, Off 
Basic setting: On

Blocks manual commissioning for the device
channel. Note: In the "Off" setting, the device
cannot be reset to the factory setting.

Local Operation

On, Off 
Basic setting: On

Blocks the device channel for local operation.

10 Troubleshooting

After a brief button actuation, the red LED flashes five times.

Cause: battery in the wall transmitter is almost empty.

Change the battery (see chapter Insert battery).

8 / 9

32579243

21.06.2019

J082579243

Summary of Contents for eNet FM 4001 M

Page 1: ...safety instructions This device or its accessories are supplied with batteries in the form of button cells DANGER Batteries can be swallowed This can lead directly to death by suffocation Danger ous s...

Page 2: ...status poll by a green LED per channel Display of the transmission status by a red LED Switch on brightness of dimmer actuators can be saved Battery powered device Signalling of transmission errors ca...

Page 3: ...0 4 seconds Dimming Press the button for longer than 0 4 seconds The dimming process ends when the button is released Switching on dimmer actuators at minimum brightness Press the bottom button for lo...

Page 4: ...he device To ensure good transmission quality keep a sufficient distance from any possible sources of in terference e g metallic surfaces microwave ovens hi fi and TV systems ballasts or trans formers...

Page 5: ...onto the base plate and snap covers on The device is ready for operation DANGER Mortal danger of electric shock During commissioning cover the parts carrying voltage on radio transmitters and ac tuat...

Page 6: ...removed The buttons of the wall transmitter are preallocated with the following scenes Release the Button allocation 1 top 1 bottom Scene 1 All Off 2 top 2 bottom Scenes 2 Scene 3 3 top 3 bottom Scen...

Page 7: ...multaneously for longer than 20 seconds Figure 4 The red status LED flashes after 4 seconds After 20 seconds the LED flashes faster Press the desired button briefly The red LED flashes more slowly The...

Page 8: ...sun protection twi light Basic setting App use Setting the type of scene used for a scene but ton Setting is always made in pairs Advanced device settings Parameters Setting options Basic setting Exp...

Page 9: ...has almost been reached For the function of the transmitter to continue the polling and display of the sum status will be switched off As soon as sufficient transmission time is available again the s...

Reviews: