2
Motor size
Motor OF311
Motor OF312
Voltage
Volt
120
20
20
120
20
20
Frequency
Hz
60
50
60
60
50
60
Power
HP
0,
0,
0,
0,60
0,60
0,60
kW
0,24
0,24
0,24
0,44
0,44
0,44
Displacement
l/min
84
67
84
168
14
168
CFM
2,97
2,7
2,97
5,9
4,7
5,9
FAD @ 8 Bar ***
l/min
4
26
4
64
58
64
CFM
1,20
0,92
1,20
2,26
2,05
2,26
Max. pressure**
Bar
6
6
6
6
6
6
PSI
90
90
90
90
90
90
Max. current
Amps
4,7
2,6
2,7
8,0
,4
,8
Weight
Kg
10
10
10
1
1
1
Lbs
22
22
22
29
29
29
Dimensions (l x w x h)
mm
20 x 140 x 240
20 x 140 x 240
Inch
9.0 x 5.5 x 9.5
12.5 x 5.5 x 9.5
Model
OF301 - 4B
OF302 - 4B
OF302 - 15B
Tank size
liter
4
4
15
US gallon
1,1
1,1
4,0
Weight
kg
19
22
25
lbs
42
49
55
Dimensions (l x w x h)
mm
90 x 10 x 50
90 x 20 x 50
80 x 80 x 50
Inch
15,5 x 12,5 x 1,5
15,5 x 12,5 x 1,5
15,0 x 15,0 x 21,0
Pumping time
(0-8 bar/0-120 psi)
@ 50 Hz sec.
90
45
165
@ 60 Hz sec.
75
40
15
Noise level @ 1 m
@ 50 Hz dB(a)
65
65
65
@ 60 Hz dB(a)
66
66
66
Model
OF302 - 25B
OF302 - 25BD2**
2*OF302 - 40B
2*OF302-40BD2**
Tank size
liter
25
25
40
40
US gallon
6,6
6,6
10,6
10,6
Weight
kg
28
46
59
lbs
62
7
101
10
Dimensions (l x w x h)
mm
80 x 80 x 610
510 x 460 x 610
560 x 450 x 610
560 x 540 x 60
Inch
15,0 x 15,0 x 24,0
20,0 x 18,0 x 24,0
22,0 x 18,0 x 24,0
22,0 x 21,0 x 25,0
Pumping time
(0-8 bar/0-120 psi)
@ 50 Hz sec.
270
25
220
260
@ 60 Hz sec.
225
250
180
220
Noise level @ 1 m
@ 50 Hz dB(a)
65
65
68
68
@ 60 Hz dB(a)
66
66
69
69
**
Displacement is reduced by approx. 18-20% on units with dryer (D). Min. pressure required to operate dryer: 6 bar
Technical modifications reserved.
The figures in the tables are based on the unit working in fairly clean air, at ambient temperatures around 20-40°C, relative humidity
near 50% and operating at sea level. The performance of the product will be adversely effected at high altitudes. For further information
on the wirings isolations class: See data table on the motor.
Technical data
Summary of Contents for 2xOF302-40B
Page 2: ......
Page 4: ......
Page 36: ......
Page 44: ...28 0070010 Dimensions OF301 60Hz 0070013 Dimensions OF301 50Hz Technical data...
Page 46: ...30 0080010 Dimensions OF302 0080011 Dimensions OF302 horizontally mounted Technical data...
Page 49: ...33 6072890 Electrical drawing model OF301 302 B D 100 240V 50 60Hz Diagrams...
Page 50: ...34 6072880 Electrical drawing model OF301V 302V 100 240V 50 60Hz Diagrams...
Page 51: ...35 6073060 Electrical drawing model 2xOF301 2x302 B 100 240V 50 60Hz Diagrams...
Page 52: ...36 6073061 Electrical drawing model 2xOF301 2x302 B D 100 240V 50 60Hz Diagrams...