4 Configuration parameters
70
4.2.6 Configuration - Recording
Parameter
Value/Selection
Description
Analog channels
Input signal
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Input signal
Analog input 1 — 6,
Math channel 1 — 6
Select which channel is to
be recorded (stored).
Channel name
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Channel name
16 characters
Analog channel 1 — 6
The channel name is
shown in the channel line
(header) for bar graph and
scaling.
Unit
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Unit
5 characters
%
Decimal place
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Decimal place
Automatic,
X.XXXX, XX.XXX,
XXX.XX, XXXX.X,
XXXXX.
Automatic: representation
with maximum resolution
Line width
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Line width
Thin,
Thick
Line width of the
measurement curve within
the graphical display
Alarm
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarm
➔
Alarm
Off,
Activated
Low limit
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarm
➔
Low limit
-99999 to 0 to +99999
High limit
Configuration
➔
Recording
➔
Analog channels
➔
Analog channel 1 — 6
➔
Alarm
➔
High limit
-99999 to 0 to +99999
Summary of Contents for LOGOSCREEN 550 cf
Page 1: ...Paperless Recorder B 70 6510 0 Operating Manual 03 08 00467986 cf...
Page 2: ......
Page 30: ...2 Device description 30...
Page 112: ...6 Rights 112...
Page 120: ...9 Installation 120...
Page 126: ...11 T V Report on Data Manipulation Security 126...
Page 127: ...127 11 T V Report on Data Manipulation Security...
Page 128: ...11 T V Report on Data Manipulation Security 128...
Page 136: ...12 Index 136...
Page 137: ......