JUMAR REG-03
Mini
PARAMETERS
SET HEATING
In this group of adjustments, the user has the ability to set the adjustments
related to temperature. Given below are the parameters you can change.
Parameter's description:
No
Parameter
name
Description
1
CH
HYSTERESIS
The value of the furnace's temperature has to decline to start
the working mode of the boiler or ignite the pellets again.
Setting the hysteresis more than 5°C is reasonable only
when heating the central heating buffer.
2
CH PUMP
TEMPERATURE
The threshold temperature of starting the pump of the
central heating (CH pump). The pump works according to
the user's settings if the input of the room thermostat is
contact. The pump is also automatically switched on if one of
the emergency status appears (e.g. overheating of the
furnace, malfunction of the sensor, reaching the protection
temperature of the furnace etc.).
- 22 -