TEMPERATURE SETTING
The controller has an ability to set heating temperature in the range of 35°C to
85°C (
KTY
sensor) or up to 300°C (
PT1000
sensor). After reaching the set
temperature, the controller switches into stand by mode or completely turns the burner
off. Decreasing the temperature below the set value (Heating water temperature - CH
boiler hysteresis) activates the burner function. If there is no flame in the burner, it will
be ignited again.
In the picture below, illustrates how change a value of temperature:
After press „MENU/OK” (1 sec.)
the temperature parameter will
start pulsating.
Using the "
UP/DOWN
" button, it
is possible to change the
temperature value.
After setting the desired
temperature, must accept the new
value by pressing the
"
MENU/OK
"