In the picture below, illustrates an example of placing sensors:
Sensor
No.
Designation
Name
Description
1
STB
STB
Sensor
STB sensor (securing sensor) has to be places in
the boiler along with the CH sensor.
2
CH
CH
Sensor
Central heating water sensor (CH).
3
FEED
Burner
Sensor
The sensor protects the burner against excessive
temperature growth. Bimetal sensor has to
selected according to the burner.
4
FIRE
Fire
Sensor
The flame sensor has to be placed so that it could
detect flame and heat in the furnace/boiler. You
should not subject it to high temperatures. When
connecting, you have to take note of polarization
of the sensor (+/-).
- 10 -