ENGLISH
60
TROUBLESHOOTING
PROBLEM CAUSE
SOLUTION
It is not possible
to turn the tool
on.
The polarity of the inserted batteries
is incorrect.
Insert the batteries as indicated by the polarity
symbols.
The batteries are spent.
Insert new batteries.
Err001 appears. The intensity of the reflected laser
beam is too high.
Do not aim the laser beam at strongly reflecting
surfaces. Cover the surface of the measurement
object with a piece of white paper, if required.
Err002 appears. Out of range.
Measure within the measurement range (0.3–50
m).
Err003 appears. The measurement object does not
reflect the laser beam correctly.
Use another measurement object or cover the
surface of the measurement object with a piece
of white paper.
Err004 appears. Temperature too high.
Wait until the tool has reached operating
temperature (0°C–40°C).
Err005 appears. Temperature too low.
Wait until the tool has reached operating
temperature (0°C–40°C).
Err006 appears. Spent batteries
Insert new batteries.
Err007 appears. The tool vibrated or moved during
measurement.
Hold the tool still during measurement.
Err008 appears. Input data fault. One of the smaller
sides in the right angled triangle is
longer than the hypotenuse.
Repeat the measurement.
Subject to printing errors and design changes over which we have no control. In the event of problems,
please contact our service department.
www.jula.com
Summary of Contents for 160-090
Page 61: ......