– 50 –
– 360˚
– 180˚
0˚
180˚
360˚
* When the point
before 1 stitch is
regarded as 0˚,
compensation is
possible by 360˚ (1
stitch) in front and in
the rear.
– 360˚
– 180˚
0˚
180˚
360˚
– 360˚
– 180˚
0˚
180˚
360˚
Set value
Compensation angle
Number of stitches of compensation
‒
36
‒
360
゜
‒
1
‒
18
‒
180
゜
‒
0.5
0
0
゜
0
18
180
゜
0.5
36
360
゜
1
Compensation of off-timing of solenoid for reverse feed stitching at the end of sewing (Function setting No. 53)
Off-timing of solenoid for reverse feed stitching at the start of sewing can be compensated by the unit of angle.
Adjusting
range
– 36 to 36 <1 / 10˚>
Compensation of timing of the solenoid for reverse feed stitching (Function setting No. 51 to 53)
When the normal and reverse feed stitches are not uniform under the automatic reverse feed stitching action,
this function can change the ON / OFF timing of the solenoid for back tack and compensate the timing.
Compensation of on-timing of solenoid for reverse feed stitching at the start of sewing (Function set-
ting No. 51)
On-timing of solenoid for reverse feed stitching at the start of sewing can be compensated by the unit of angle.
Adjusting
range
– 36 to 36 <1 / 10˚>
Compensation of off-timing of solenoid for reverse feed stitching at the start of sewing (Function setting No. 52)
Off-timing of solenoid for reverse feed stitching at the start of sewing can be compensated by the unit of angle.
Adjusting
range
– 36 to 36 <1 / 10˚>
Set value
Compensation angle
Number of stitches of compensation
‒
36
‒
360
゜
‒
1
‒
18
‒
180
゜
‒
0.5
0
0
゜
0
18
180
゜
0.5
36
360
゜
1
Set value
Compensation angle
Number of stitches of compensation
‒
36
‒
360
゜
‒
1
‒
18
‒
180
゜
‒
0.5
0
0
゜
0
18
180
゜
0.5
36
360
゜
1
Holding time of lifting presser foot (Function setting No. 47)
Solenoid type presser foot lifter can adjust the holding time control of lifting presser foot.
This function automatically lowers the presser foot when the time set with the setting No. 47 has passed
after lifting the presser foot.
When the pneumatic type presser foot lifter is selected, the holding time control of lifting presser foot is lim-
itless regardless of the set value.
Setting
range
10 to 600 sec <10 / sec>
4
7
6
0
5
1
–
8
5
2
1
0
5
3
1
5
Summary of Contents for SC-920