– 8 –
(4) Explanation of operation panel CP-180
1) Reverse stitching pattern
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Sewing pattern
1. Press reverse stitching pattern switch
to
specify the reverse stitching pattern.
2. The reverse stitching pattern is selected, and
the number of stitches and data on reverse
stitching which have already been specified are
shown on the panel.
3. If you want to change the number of stitches,
operate the " + " or " - " switch of switches
for
setting the number of stitches A through D.
(The range of the number of stitches that can
be changed : 0 to 19 stitches)
4. Four different stitching patterns can be
performed by matching the ON and OFF settings
of automatic reverse stitching (for start) switch
and automatic reverse stitching (for end)
switch
.
5. Furthermore, the double reverse stitching can
be selected by operating double reverse
stitching (for start) switch
and double reverse
stitching (for end) switch
.
A
B
D
C
D
C
A
B
Summary of Contents for SC-920
Page 1: ...SC 920 40089311 No E393 00 ENGINEER S MANUAL...
Page 71: ...67 2 IP 110F operation panel block diagram...
Page 73: ...66 MEMO...