– 72 –
All contents of function setting of SC-910N can be
returned to the standard set values.
1) Pressing all switches
,
and
inside the
front cover, turn ON the power switch.
2) LED displays indication
with the sound “peep”,
and initialization starts.
3) The buzzer sounds after approximately one sec-
ond (single sound three times, “peep”, “peep”, and
“peep”), and the setting data returns to the stan-
dard setting value.
(Caution) Do not turn OFF the power on the way
of initializing operation. Program of the
main unit may be broken.
4) Turn OFF the power switch and turn ON the power
switch after closing the front cover. The machine
returns to the normal motion.
(Caution)
1. When this operation is performed, the neu-
tral compensation value of the pedal sen-
sor becomes “0”. Accordingly, be sure to
execute the operation of automatic pedal
sensor neutral compensation before using
the sewing machine. (Refer to 6. - (4).)
2. Even when this operation is performed, the
sewing data set by the operation panel can-
not be initialized.
9. INITIALIZATION OF THE SETTING DATA