– 37 –
[ Moving procedure to the function setting mode ]
1. Hold pressing / switch
, and press
switch
to move to the function setting mode.
(Caution) Function setting No. 2 is displayed imme-
diately after the changeover.
2. When returning to the normal mode, press /
switch
and determine the contents of the
setting.
(1) Material end sensor function setting (Function set-
ting No. 2)
It is rendered effective when connecting the optional
material end sensor
It is possible to change the set value with switch
or switch
.
0 : Material end sensor function is prohibited.
1 : Material end sensor function is effective.
When “1” is selected, material
end sensor display lights up when
the mode has returned to the nor-
mal one.
(2) Thread trimming operation after material end stop
setting (Function setting No. 3)
Press / switch
to advance to the function
setting No. 3.
It is possible to change the set value with switch
or switch
.
0 : Material end stop
1 : Automatic thread trimming after detection of
material end
When “1” is selected, the auto-
matic thread trimming display
lights up when the mode is re-
turned to the normal one.
3) Special setting
In addition to the normal function setting procedure at the front panel, it is possible to change the set value by
directly moving to the function setting mode while the power is turned ON.