![JUKI PS-900-13090 Instruction Manual Download Page 65](http://html1.mh-extra.com/html/juki/ps-900-13090/ps-900-13090_instruction-manual_2029452065.webp)
– 62 –
Classifica
-
tion of pa-
rameters
No.
Parameter name
Range
Standard
value
Meaning of parameter and comment
Reset
setting
P39
Return-to-origin speed
(mm/min)
100 to 60000
15000
x, y axes speed during resetting to the
origin
P756-
P761
Output I/O setting be-
fore resetting
OUT1 to OUT6 /
No
No
Setting of IO before resetting
P762-
P797
High level / Low
level
High level
P649
Alarm in the case of a
resetting error
Yes/No
No
P782-
P787
Output IO setting after
resetting
OUT1 to OUT6 /
Not set
Not set
Setting of IO after returning to the origin
P788-
P793
High level / Low
level
Low level
Setting of
stop
P40
Automatic thread trim-
ming during temporary
stop
Yes/No
Yes
Whether automatic thread trimming is
performed at temporary stop
P41
Needle position during
temporary stop
Upper stop posi-
tion
/ Lower stop
position
Upper
stop posi-
tion
Needle bar position when temporary
stop
P45
Temporary stop switch
type
Yes/No
No
This parameter specifies whether the
clamp is lifted at the time of pause.
Self lock / Normal Self lock
Soft type of temporary stop, self-lock-
ing and normal
"Normal" automatically bounces when
touched
P799
Presser foot is not lifted
during temporary stop
Yes/No
No
Statistics
settings
P49
Bobbin thread remain-
ing amount is cleared at
the time of turning the
power ON
Yes/No
No
Whether the remaining amount of
bobbin thread is reset to 0 (zero) when
turning the power ON
P50
Operation stops after
the bobbin thread has
run out
Yes/No
Yes
In the case of "Yes", the sewing ma-
chine stops when the consumed bobbin
thread length has reached the "entire
length".
P51
Bobbin thread counter
setting is enabled
Yes/No
Yes
In the case of "Set", statistics automat-
ically indicate the consumed bobbin
thread length
P46
Bobbin thread counter
is cleared at the time of
turning the power ON
Yes/No
Yes
Whether the sewing counter is reset to
0 (zero) when turning the power ON
P47
Operation continues
after the counter has
reached the set value
Yes/No
Yes
Whether the operation is continued after
the sewing counter has reached the set
value
P48
Counter setting is en-
abled
Yes/No
Yes
Whether the sewing counter is enabled
P52
Working hours counter
Yes/No
Yes
In the case of "Yes", the machining time
statistics function is enabled
P779
Bobbin thread count
mode
IN1 to IN4 / de-
fault
Default
Statics mode of the bobbin thread
amount
P780
Adjustment value of
the surplus amount of
bobbin thread (mm)
0 to 600000
0
Adjustment of the bobbin thread remain-
ing amount