– 5 –
(2) Installing the regulator
1) Install regulator (asm.)
❶
on mounting plate
❺
with
screw
❷
, spring washer
❸
and nut
❹
which are
supplied with the unit.
2) Install couplings
❻
and
❼
on regulator
❶
.
3) Attach mounting plate
❺
on the undersurface of the
table with accessory screws
❽
supplied with the
plate.
4) Connect ø6 air tube coming from the sewing ma-
chine to coupling
❻
.
❷
❶
❺
❻
❼
❹
❸
❽
(1) Routing the air tube and cables
Pass the air tube and cables
❶
through hole
❷
in the
table down to the undersurface.
If humidity is high, water may leak from ø8 air tube
❸
for exhaust coming from the sewing machine.
(3) Adjusting the air pressure
1) The operating air pressure is 0.5 to 0.55 MPa.
Adjust the air pressure using air pressure regulating
knob
❶
of the filter regulator.
2) In the case fluid accumulation is observed in
A
sec-
tion of the filter regulator, turn drain cock
❷
to drain
the fluid.
Decrease
Increase
❶
❷
A
2-3. Pneumatic components
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the follow-
ing work after turning the power off and ascertaining that the motor is at rest.
❸
❶