1. List of setting items
Selecting
device
Item
Setting
range
Contents
Set value at the
time of shipment
T0
(Timer)
Needle thread
trimming time
1 to 50 Sets the period of time between the detection of the lower end by
the needle thread trimmer cylinder and the start of rising.
This value is set in increments of 0.1 s. (Set value: 5 → 0.5 s)
3
T1
(Timer)
Bobbin thread
trimming time
1 to 50 Sets the period of time between the detection of the extruding end
by the bobbin thread trimmer cylinder and the start of retraction.
This value is set in increments of 0.1 s. (Set value: 5 → 0.5 s)
3
T2
(Timer)
Heater tempera-
ture setting
0 to 200 Sets preheat time of the heater.
Thread trimming operation is not started until this time has passed.
This value is set in increments of 0.1 s. (Set value: 5 → 0.5 s)
0
DM0
Selection of
sewing machine
operation when
an error occurs
00000 Upon occurrence of a fault, the sewing machine is temporarily
stopped. Temporary stop cannot be cancelled unless the no bob-
bin-thread detection and stitch skipping detection are reset.
00000
00001 Even if a fault occurs, the sewing machine continues operation. It
should be noted, however, the next start of sewing will be disabled
unless the fault is reset.
DM1
Selection of
enable/disable
detection of stitch
skipping and
bobbin thread
00000 Enables the stitch skipping detection and bobbin thread detection
00000
00001 Disables the stitch skipping detection
00002 Disables the bobbin thread detection
00003 Disables the stitch skipping detection and bobbin thread detection
DM2
Selection of
enable/disable
of bobbin-case
confirmation
00000
Checks presence/absence of the bobbin case at the startup of sew
-
ing machine
If the bobbin case is absent, the sewing machine cannot be started.
00000
00001 Does not check presence/absence of the bobbin case at the startup
of sewing machine
DM5
Number of stitch-
es for ignoring
stitch skipping
detection
0 to
65535
Sets the number of stitches to be sewn before stitch skipping detec-
tion is started
Stitch skipping is ignored from the start of sewing until the set num-
ber of stitches is reached.
00003
1) Press the
key to select DM as a select-
ed device.
* When changing the timer, select T/C.
2) Specify the device number with the / key.
3) Keep the
key held pressed for three sec-
onds.
4) Press the
key to blink the digit to be
changed.
5) Increase/decrease the numeric value with the
/ key to set a desired set value.
6) Keep the
key held pressed for three
seconds to register the set value. Then, the
access window returns to the previous state.
Access window
DM
Selected
device
Device
number
Inside of
control panel
Rear face of
control panel
2. Setting procedure
Specified value
Set value
Summary of Contents for LK-1942ZA5050
Page 2: ......
Page 3: ......
Page 34: ... 24 IX ユニット品番 部品名 品番 備考 上熱線装置 40121875 下熱線装置 40121876 ボビンケース装着検知装置 40121877 ...
Page 35: ... 25 部品名 品番 備考 糸たぐり装置 40121878 下糸無し検知装置 40121880 40122405 制御装置 40122659 目飛び検知装置 ...
Page 39: ......
Page 40: ......
Page 77: ......
Page 113: ......
Page 149: ......
Page 185: ......
Page 221: ......
Page 252: ... 24 IX 组件货号 零件名称 货号 备考 上热线装置 40121875 下热线装置 40121876 梭壳安装检测装置 40121877 ...
Page 253: ... 25 零件名称 货号 备考 拉线装置 40121878 无底线检测装置 40121880 40122405 控制装置 40122659 跳针检测装置 ...