KE2000 Installation Manual
11
2.
Loosen three hexagon
socket head bolts of each
adjuster.
(Make sure that the adjust
foot moves freely.)
3.
When the adjusters are
raised from adjuster (1), (3),
(2), (4), (1), and so on in
that order, this ensures
relatively smooth raising of
the machine level.
4. Level the machine in the
back and forth direction.
Put a level vial in the state
shown by dotted lines and
move the vertically adjusters
(1)
・
(2)
、
(3)
・
(4) in that order
so that the scale on the level
vial shows the set value stated in the level setting table (supplied with the machine)
±
1.
The transport height is adjusted to 900 mm for domestic models and 950 mm for
overseas models.
5.Next, level the machine in the
horizontal direction. Put a level
vial in the state shown by
continuous lines and vertically
move the adjusters (1)
・
(4)
、
(2)
・
(3) in that order so that the scale
on the level vial shows the set
value stated in the level setting
table (supplied with the machine)
±
1.
6.Repeat above steps 4 and 5 to
level the machine so that the level
on the base bar B enters the
standard range.
(The scale of the level vial to be used
for this adjustment is 0.05/div.)
Fig
4-1-4
Viewed from the bottom
Viewed from the top
Fig
4-1-5
Base bar B
Base bar R
Base bar F
Level vial