51
−
Troubles
Cause (1)
Cause (2)
Checking orders and corrective measures
From the previous page
Irregular stitches
Defective feed
Defective feed
Height of feed dog is too high and jumping
of the feed dog occurs at high speed.
Abration of top ends of teeth of feed dog
Feed dog pitch is too coarse.
Tilt of feed dog is defective.
Parallelism of feed dog is defective.
Number of revolution is too high.
Others
Height of feed dog is too high.
Locus of feed dog is defective.
Abration of top ends of teeth of feed dog
Feed dog pitch is to coarse.
Tilt of feed dog is defective.
Lower the height of feed dog (standard 0.8 mm), or increase the
pressure of the presser foot to protect it from jumping.
Sharpen the top ends of teeth with diamond file or the like, or
replace it with a new one.
Replace the feed dog with one with fine pitch.
Change the position of feed driving base pin, and tilt the feed
dog with its front up to make the puller effect.
Replace the feed dog.
Decrease the number of revolution.
Use a gauge having a small clearance between groove of throat
plate and moving direction of feed dog in the range that the feed
dog does not come in contact with the throat plate when the feed
dog is moving if the feed dog pitch is small.
Lower the height of feed dog (standard 0.8 mm), or increase the
pressure of the presser foot to protect it from jumping.
Adjust the feed driving cam timing referring to [Adjusting feed
timing and dimensions of the feed base].
Adjust the feed driving cam to marker line (-).
Sharpen the top ends.
Use the feed dog with fine pitch.
Tilt the feed dog with its front down.
To the next page
▼