– 82 –
3-2. Initial value list
No.
Item
Initial value
4530/6030
Maxmum sewng speed
2500
Sewng speed of 1st sttch (In case of wth thread clamp)
1500
Sewng speed of 2nd sttch (In case of wth thread clamp)
2500
Sewng speed of 3rd sttch (In case of wth thread clamp)
2500
Sewng speed of 4th sttch (In case of wth thread clamp)
2500
Sewng speed of 5th sttch (In case of wth thread clamp)
2500
Thread tenson of 1st sttch (In case of wth thread clamp)
200
Thread tenson settng at the tme of thread trmmng
0
Thread tenson changeover tmng at the tme of thread trmmng
0
Sewng speed of 1st sttch (In case of wthout thread clamp)
200
Sewng speed of 2nd sttch (In case of wthout thread clamp)
600
Sewng speed of 3rd sttch (In case of wthout thread clamp)
1000
Sewng speed of 4th sttch (In case of wthout thread clamp)
1500
Sewng speed of 5th sttch (In case of wthout thread clamp)
2000
Thread tenson of 1st sttch (In case of wthout thread clamp)
0
Thread tenson changeover tmng at the tme of sewng start (In case of
wthout thread clamp)
–5
Heght of presser at the tme of 2-step stroke
35
Buzzer sound can be prohbted.
Number of sttches of thread clamp release s set.
2
Clampng tmng of thread clamp can be delayed.
0
Thread clamp control can be prohbted.
Feed moton tmng s selected.
3
State of the presser after end of sewng s selected.
Presser lftng moton at the end of sewng can be set.
Orgn retreval can be performed every tme after end of sewng (other
than combnaton sewng).
Orgn retreval n combnaton sewng can be set.
State of presser when sewng machne stops by temporary stop
command can be selected.
Needle stop poston s set.
Thread trmmng can be prohbted.