JUDO JUKO-LongLife
15
Faults
charged into the drinking water when the
domestic water station station is
switched back on. The health of people
who drink dirty water is at risk.
–
Store the domestic water station station
in frost-free conditions! Frost can cause
any water contained in the domestic
water station station's voids to freeze
and thus cause mechanical damage to
the domestic water station station so that
it leaks at operating pressure or can
burst. Leaking water can cause major
damage to the building. In addition, peo-
ple near the domestic water station sta-
tion can be injured by breaking off filter
parts.
–
When restarting the domestic water sta-
tion station, follow the instructions for a
new domestic water station station.
6.
Faults
The opening of the units and the replace-
ment of the water pressure charged parts
may only be effected by authorized per-
sonal in order the ensure the unit secu-
rity and its tightness.
Help with faults:
Fault
Cause
Remedy
Backwashing water con-
tinues running!
Ceramic flushing valve not
fully closed.
Repeat the backwashing and
then turn the handwheel until it
locks into place!
Dirt in the ceramic flushing
valve.
Water flow rate falls!
Screen is blocked.
Carry out backwashing.
Leaks in the domestic
water station!
Inform the fitter or nearest cus-
tomer service centre. (The filter
cover must be replaced imme-
diately.)
Filter cover becomes
turbid!
Filter cover has been
exposed to high tempera-
tures or solvents.
Hairline cracks on the
filter hood!
Downstream pressure
slowly rises when no
water flowing!
Impermissible increase in
pressure due to service
water heating
Check the safety valve of the
hot water boiler. Inform the fitter
or nearest customer service
centre.
Wear in the pressure
reducer cartridge.