JUDO JUKO-LongLife
7
Installation
–
The ambient temperature must not
exceed 30 °C (86 °F)! At higher
temperatures or direct sun radiation the
material can be damaged and the filter
hood can even break.
–
In order to be able to safely discharge
the wastewater in operation and in case
of any defects that occur in the system,
precise compliance with the details
given in the chapter “Installation” is
necessary!
–
If the wastewater (backwashing) cannot
be safely and completely discharged,
the house and installations can be dam-
aged by water.
–
A shut-off valve must be installed
upstream and downsteam of the domes-
tic water station with a bypass to allow
continued water supply when the
domestic water station is out of service!
This enables the water supply to the
domestic water station to be interrupted
during installation, servicing/mainte-
nance, repairs and in case of malfunc-
tions. Floods and serious water damage
to house installations can therefore be
avoided.
–
The unit can be installed in all standard
drinking water pipes.
–
It is not permitted to install the domestic
water station upstream of the water
meter!
4.1.2 Installation position
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
Always install the domestic water station in
a vertical position (± 5°)!
Failure to observe this can cause uncon-
trolled backwashing water to escape and
can result in water damage.
4.1.3 Mounting the built-in rotary
flange
Install using the supplied built-in rotary
flange. The built-in rotary flange is used as a
connecting element between the pipe and
the domestic water station.
It is suitable for both horizontal and vertical
pipes.
The built-in rotary flange must be
installed in the direction of flow. This is
marked by a cast in arrow.
Failure to comply with this means the
domestic water station cannot work.
The flange surface of the built-in rotary
flange must be in a vertical position! The
built-in rotary flange must be fitted so that
mechanical stresses cannot occur! Other-
wise mechanical damage can result in the
built-in rotary flange. Otherwise mechanical
damage can result, the pipe may burst or the
built-in rotary flange can break. This can
result in major water damage.
In this case, people close to the domestic
water station are exposed to a health risk
due to the large quantities of water.
Therefore, during installation, ensure that no
large forces act on the pipe, built-in rotary
flange and domestic water station.
4.1.4 Installing the domestic water
station
Fig. 2: Built-in rotary flange with bayonet fixture
I
II