JUDO JUKO-LongLife
17
Data sheet
9.
Data sheet
9.1
Type
JUDO JUKO-LongLife
domestic water station
Abbreviated name: JUKO-LF
9.2
Models
9.3
Technical specifications
The following applies for all the models of
the device:
–
Maximum ambient temperature and
water temperature: 30 °C (86 °F).
–
The water to be filtered must possess
quality of drinking water!
–
Threaded connection to DIN EN
10226-1.
The nominal pressure denotes the pressure
class, according to which the domestic
water station must fulfil the requirements to
DIN EN 13443-1, DIN 19628 and DIN EN
1567. The maximum operating pressure is
lower, in order to ensure the optimum func-
tion of the domestic water station.
The backwashing volumetric flow given
applies to 29 - 44 psi (200 - 300 kPa) mains
pressure and for a completely opened
flushing water valve.
Model
Order no.
JUKO-LF ¾"
8170310
JUKO-LF 1"
8170311
JUKO-LF 1¼" -
JUKO-LF 1½" -
JUKO-LF 2" -
Nominal pressure
Model
Operating
pressure
Nominal
pressure
JUKO-LF
¾" – 2"
22 - 145 psi
(150 - 1000 kPa)
PN 16
Weight
Model
Weight
JUKO-LF ¾" 2.9
kg
JUKO-LF 1" 3.1
kg
JUKO-LF 1¼" 3.4
kg
JUKO-LF 1½" 8.1
kg
JUKO-LF 2" 8.6
kg
Water flow rate
Model
Water flow rate up to
JUKO-LF ¾"
2.3 m³/h (10 gpm)
JUKO-LF 1"
3.6 m³/h (16 gpm)
JUKO-LF 1¼"
5.8 m³/h (25.5 gpm)
JUKO-LF 1½"
9.1 m³/h (40 gpm)
JUKO-LF 2"
14.0 m³/h (61.5 gpm)
Back-flush volume stream
Model
Back-flush
volume stream
JUKO-LF ¾"
0.3 l/s (5 gpm)
JUKO-LF 1"
0.3 l/s (5 gpm)
JUKO-LF 1¼"
0.3 l/s (5 gpm)
JUKO-LF 1½"
0.3 l/s (5 gpm)
JUKO-LF 2"
0.3 l/s (5 gpm)