22
JUDO FIMAT
Data sheet
9.3
Technical data
The following applies for all the models of
the device:
–
Maximum ambient temperature and
water temperature: 30 °C (86 °F)
–
Threaded connection to DIN EN 1092-1
Power requirements
Current supply
230 V AC / 50 Hz
Rated input during
backwash
max. 15 W
Weight
Model
Weight
JFXL-M
1½"
17.5 kg
JFXL-M
2"
18.8 kg
JFXL-T
1½"
18.4 kg
JFXL-T
2"
19.7 kg
JFXL-TP
1½"
18.8 kg
JFXL-TP
2"
20.1 kg
Nominal pressure
Model
Operating
pressure
Nominal
pressure
JFXL
1½" - 2"
22 - 150 psi
(150 - 1034 kPa)
PN 10
Nominal flow rate
Model
Nominal flow rate
1)
after back-
washing at a pressure loss of
3 psi (20 kPa) and clean sieve
1) Information on water flow apply to drinking
water. For service water and more polluted
water the maximum water flow is lower, de-
pending on the chosen mesh size. It then has
to be chosen a bigger mesh size.
JFXL
1½" - 2"
88 gpm (US.liq.gal.)
73 gpm (Imp.gal.)
20 m³/h
Backwashing volumetric flow
Model
Backwashing volumetric flow
1)
1) The backwashing volumetric flow given ap-
plies to 29 - 44 psi (200 - 300 kPa) mains
pressure and for a completely opened flush-
ing water valve.
JFXL
1½" - 2"
8 - 24 gpm (US.liq.gal.)
6.5 - 20 gpm (Imp.gal.)
0.5 - 1.5 l/s
Summary of Contents for FIMAT JFXL-M 1 1/2