18
JUDO BIOSTAT-COMBIMAT
Operation
5.4
Cleaning - Flushing
Depending on the quality of the water and
the operating methods, a thin coating of lime
is formed on the brush in the treatment
chamber. This lime layer must be removed
and flushed out of the water treatment
devices at regular intervals.
The water treatment device has a device for
flushing the brush and a flush valve for
rinsing out the lime particles.
Cleaning and flushing is carried out auto-
matically by two electric motors.
During Cleaning - Flushing, the yellow LED
2 lights up.
The Cleaning - Flushing can be started
manually by operating the manual push-
button (2).
5.5
Warning message "Battery
low"
To ensure that Cleaning - Flushing is carried
out completely, even in case of a power
failure, the water treatment appliance has a
9V block battery installed as an emergency
power supply.
Before each Cleaning - Flushing a battery
test will be effected. A missing, unloaded or
defective battery is indicated by the flashing
of the red LED 4. A trigging of the container
flushing is then not possible.
5.6
Mounting of the panelling
Dismantling:
–
Withdraw the upper / inferior clamping
fixture.
–
Carefully pull apart the right and the left
panel parts by the handle cavities on
the back of the panelling.
–
Remove the type plate and the panel-
ling.
Assembly:
–
Push the right and left parts of the panel-
ling together till a gap of approximately
15 mm is left.
–
Ensure that the cable is not trapped!
–
Refit the type plate in the blanks, of the
panelling, situated above and below.
–
Push the panelling completely together.
5.7
Replacing the batteries
When a change of batteries is necessary
(LED 4 flashes) the following procedure is
adopted:
Make sure that the drain connec-
tion is functional before plug-
ging the power supply into
the socket (see chapter “Dis-
charging the flushing water”).
Disconnect the power supply
from the socket.
Plug the power supply into
the socket!