4.7 The terminal barrel must be correctly bell-mouthed.
The (A) portion of the barrel must be bell-mouthed.
The (B) portion of the barrel is not necessarily to be bell-mouthed.
The (C) portion must be free of cracks.
4.8 The terminal must be cut at the correct position.
The projection is too long.
The insulation barrel of the subsequent terminal is deformed.
The projection should be 0.2 to 0.5 mm.
The mating part is deformed.
Excessive Cutting