![JSP P5310 Manual Download Page 8](http://html1.mh-extra.com/html/jsp/p5310/p5310_manual_2028749008.webp)
- 8 -
Low-Cost Programmable Transmitters P5310, P5311 with LHP Communication
5. Product specifications
5.1 Technical specifications
Supply voltage:
P5310
9 to 35 V
SS
P5311
11 to 35 V
SS
Version EI1
11 to 30 V
SS
(internally protected against polarity inversion and short-
term overvoltage)
Range of ambient temperatures: -40 to 85 °C
Reference ambient temperature: 23 ± 5 °C
Housing:
Version H1x
IP40, terminals IP00 after
installation to the head the
housing is given by the design
of the head
Version L1x
IP20
Humidity:
Version H1x
0 to 100 % RH with condensation
after installation to the head
Version L1x
10 to 80 % RH without
condensation
Connection of wires:
Screw terminals for cross section 0,5 to 1,5 mm
2
,
torque 0,5 Nm.
Warm-up time:
5 s
Time for re-programming of range using a PC:
5 s
Time for re-programming of sensor type using a PC: 5 s
Type of DIN rail:
TS 35 according to DIN 46277
Dimensions (VxŠxH):
H1x
Ø 44 x 24 mm
L1x
17.5 x 62.5 x 64 mm
Material of cases:
H1x
polycarbonate
L1x
polyamide
Weight:
H1x, L1x
40 g
Working position:
arbitrary
Input
Input ranges:
Input type
Basic range
Standard
RTD input
0 to 400 Ohm
---
RTD input
0 to 4000 Ohm
---
potentiometer
40 to 400 Ohm
---
potentiometer
400 to 4000 Ohm
---
voltage input
-15 to 70 mV
---
Pt100
-200 to 850 °C
IEC 60751
Pt500
-200 to 850 °C
IEC 60751
Pt1000
-200 to 850 °C
IEC 60751
Ni100
-60 to 250 °C
DIN 43760
Ni1000
-60 to 250 °C
DIN 43760
thermocouple “J“
-200 to 1200 °C
IEC 584-1
thermocouple “K“
-200 to 1300 °C
IEC 584-1
thermocouple “N“
-200 to 1300 °C
IEC 584-1
thermocouple “R“
-50 to 1700 °C
IEC 584-1
thermocouple “S“
-50 to 1700 °C
IEC 584-1
thermocouple “T“
-250 to 400 °C
IEC 584-1
thermocouple “B“
100 to 1800 °C*
IEC 584-1
thermocouple “E“
-200 to 950 °C
IEC 584-1
thermocouple “L“
-200 to 900 °C
DIN 43710
thermocouple “C“
0 to 2300 °C
N.I.S.T. Monograph
175
* ... range can be set from 0 °C
Digital accuracy:
Input 0 to 400 Ohm
≤ ±0.1% SR or ≤ ±0.08 Ohm
nebo odpovídající teplota
Input 0 to 4000 Ohm ≤ ±0.1% SR or ≤ ±0.8 Ohm
r corresponding temperature
Input -15 to 70 mV
≤ ±0.1% SR or ≤ ±0.02 mV
r corresponding temperature
(the greatest value is valid; SR ... Span of set range
accuracy of measured value of digital output LHP)
Input signal:
Resistance signal of temperature sensor or
potentiometer, voltage signal of thermocouple
Sensor connection:
Resistance sensor
two-, three-, four-wire
Voltage sensor (TC)
two-wire
Potentiometer
three-wire or four-wire
Compensation using
an external sensor
two-wire
Maximum wire resistance for resistance ranges: :
< 20 Ohm (each wire)
Current through resistance sensor:
< 0.15 mA
Input overloading:
Max. 24 VDC or max. 18 mA between any inputs
(max 60 s)
Cold junction compensation error:
< ±1 °C
Effect of wire resistance for resistance ranges:
Two-wire connection
can be compensated by
constant value
Three-wire connection
no effect with identical
values of wire resistance
Four-wire connection
no effect with specified
wire resistance range
Input resistance:
> 10 MOhm
Output
Output signal:
Two-wire 4 to 20 mA or 20 to 4 mA
Total measurement error on the analogue output of P5310:
Range 0 to 400 Ohm ≤ ±0.1% SR or ≤±0.08 Ohm
or corresponding temperature
Range 0 to 4000 Ohm ≤ ±0.1% SR or ≤ ±0.8 Ohm
or corresponding temperature
Range -15 to 70 mV ≤ ± .1% SR or ≤ ±0.02 mV
or corresponding temperature
Range Pt100, Pt1000, Ni100, Ni1000
≤ ±0.1 % SR or ≤ ±0.2 °C
Range Pt500
≤ ±0.1 % SR or ≤ ±0.4 °C
Range TC J, K, T, E, L typ. ≤± 0.1 % SR or 0.5 °C
Range TC R, S, B, C typ. ≤± 0.1 % SR or 2 °C
(the greatest value is valid)