1. General instructions and information

1.1 Symbols used

 

-  Warning symbol; for safe use proceed according

 

to the instructions 

 

-  The symbol CE approves conformity of the product 

 

with legal requirements

 

-  Symbol ”Output“ 

 

-  Symbol “Power supply”

 

-  T

his product does not belong to public waste

 

 

and it is 

subjected to separate collection

 

-  The product meets requirements for explosion  

 

hazard environment according to the further  

 

specification

 LHP 

-  Remote communication protocol for reading 

 

and changing of the configuration

1.2 Safety cautions and warnings

The  transmitter  shall  be  powered  from  a  safe  voltage 
source  that  meets  all  requirements  of  the  standard 
EN  61010-1  and  installed  in  compliance  with  national 

requirements and standards providing safety.
The equipment may only be installed by a qualified personnel 
who are familiar with national and international laws, directives, 
standards  and  with  the  instructions  manual.  The  instrument 
may not be used for other purposes than as specified in this 
instructions manual.
For  elimination  of  a  risk  of  injury  from  electric  shock  or  fire 
the  maximum  operational  parameters  of  the  instrument  may 
not be exceeded, particularly range of operating temperature 
because  of  exposure  to  heat  from  connected  or  surrounding 
technological equipment must not be exceeded!
The  transmitter  should  be  installed  in  suitable  environment 
without  any  direct  sunlight,  occurrence  of  dust,  high 
temperatures, mechanical vibrations and shocks and protected 
against rain and excessive moisture.

1.3 Scope of delivery

With the product is delivered:

 

- Manual for installation, operation and maintenance

 

- Certificate of calibration (only with calibrated transmitters)

 

- Copy of EC certificate on type examination ATEX   

(only transmitters for explosion hazard environment)

1.4 Description of the delivery and packing

The  product  is  packaged  in  a  protective  cover  and  provided 
with  an  identification  label  with  a  mark  of  the  output  control. 
The product must not be exposed to direct rain, vibrations and 
shocks during transport.

1.5 Storage

The  products  shall  be  stored  at  temperatures  from  -40  to 
+80 °C without condensation of water vapours.

1.6 Installation and commissioning

During installation, commissioning, operation and maintenance 
follow the instructions in chapter 4.

1.7 Spare parts

Any of the compact parts of the product can be also ordered 
as a spare part if there are not required special procedures or 
technological operations for the exchange.

1.8 Repairs

Products  are  repaired  by  the  manufacturer. The  products  for 
repair should be sent with description of the fault or defect in 
a packing that guarantees damping of shocks and vibrations 
and protects against damage during transport.

1.9 Warranty

Products  are  covered  by  a  warranty  for  a  period  of  3  years 
from the delivery date on the delivery note. The manufacturer 
guarantees  technical  and  operational  parameters  of  the 
products  within  scope  of  the  applicable  documentation. 
Warranty period is specified with individual items and begins 
from  the  day  of  takeover  of  the  goods  by  the  purchaser  or 
delivery to the carrier. Any claims concerning to defects of the 
goods  together  can  be  filed  in  writing  with  the  manufacturer 
within  the  warranty  period  and  the  claimed  product  shall  be 
presented. The  claiming  party  shall  give  identification  of  the 
product,  number  of  the  delivery  note  and  description  of  the 
fault or defect. 
The  manufacturer  is  not  responsible  for  any  defects  caused 
by  improper  storage,  incorrect  connection,  damages  caused 
by  external  effects,  in  particular  by  effects  of  factors  with 
excessive  values,  unqualified  installation,  improper  operation 
or common wearing.

2. End of service and disposal

2.1 End of service

Dismounting  and  disposal  of  the  device  is  possible 
after  disconnecting  of  power  supply  voltage.

2.2 Disposal

The  product  does  not  contain  any  environmentally 
harmful  parts.  When  disposing  the  packing  and 
destroyed  or  irreparably  damaged  product  proceed 

according to the local regulations.

Summary of Contents for P5310

Page 1: ...www jsp sk This document applies to serial numbers 10090000 and higher One type of transmitter for all common resistance and thermocouple sensors Linearized output signal 4 to 20 mA Accuracy from 0 1...

Page 2: ...4 Installation operation and maintenance 4 1 Installation and commissioning 6 4 2 Description of setting and configuration using the communicator LHPWinCom 7 4 3 Description of setting and configurati...

Page 3: ...e cover and provided with an identification label with a mark of the output control The product must not be exposed to direct rain vibrations and shocks during transport 1 5 Storage The products shall...

Page 4: ...minal block temperature or by the entered constant temperature The inner sensor guarantees maximum accuracy and stability of cold junction temperature measurement If required compensation using an ext...

Page 5: ...5 Low Cost Programmable Transmitters P5310 P5311 with LHP Communication 3 3 Dimensional drawings Version P531x H1x Version P531x L1x 3 4 Block diagram...

Page 6: ...ctrostatic charging Such case may be a metal temperature sensor head or a suitable metal installation box if it does not contain magnesium nor titanium During installation it is also necessary to resp...

Page 7: ...the input quantity The fixed output mode can be closed by the program button or by disconnecting of the transmitter power supply Transmitters in version EI1 or EN2 Ex version can be set up using the c...

Page 8: ...0 to 400 C IEC 584 1 thermocouple B 100 to 1800 C IEC 584 1 thermocouple E 200 to 950 C IEC 584 1 thermocouple L 200 to 900 C DIN 43710 thermocouple C 0 to 2300 C N I S T Monograph 175 range can be se...

Page 9: ...esponding temperature 10 C Range 0 to 4000 Ohm 0 1 SR or 0 8 Ohm or corresponding temperature 10 C Range 15 to 70 mV 0 1 SR or 0 02 mV or corresponding temperature 10 C the greatest value is valid Lon...

Page 10: ...RTMod Miniature HART modem with galvanic isolation USB RS232C Communication interface for to USB port of the PC PT1000A Compensation resistor Pt1000 30 to 150 C for external compensation of thermocoup...

Page 11: ...JSP Industrial Controls JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Reviews: