JSP P5310 Manual Download Page 10

- 10 -

Low-Cost Programmable Transmitters P5310, P5311 with LHP Communication

Output (current loop, terminal 5 and 6): 
 

U

i

 = 30 VDC

 

I

i

 = 100 mA

 

P

i

 = 0.9 W

 

L

i

 = 350 µH

 

C

i

 = 0 nF

Output test (terminal 6 and 7; it is designed only for temporary 
connection of a multimeter): 
 

U

o

 = 30 VDC

 

I

o

 = 100 mA

 

P

o

 = 0.9 W

 

L

o

 = 100 µH

 

C

o

 = 0 nF

Input for a sensor:
 

U

o

 = 6.6 VDC

 

I

o

 = 21 mA

 

P

o

 = 0.034 W

 

L

o

 = 70 mH

 

C

o

 = 1 µF

For other conditions see paragraph 4.1.2.

6.5 Limiting conditions of use of a transmitter 
in version with code EN2

See paragraph 4.1.3.

Type

 Description

P5310

 Low-cost programmable transmitter with LHP protocol without galvanic isolation (accuracy 0,1 %)

P5311

 Low-cost programmable transmitter with LHP protocol with galvanic isolation (accuracy 0,15 %)

Code

 Version

H10

 Into head B according to DIN, universal for resistance sensors and thermocouples

H11

 Into head B according to DIN, only for resistance sensors

L10

 On the rail TS 35, universal for resistance sensors and thermocouples

L11

 On the rail TS 35, only for resistance sensors 

Code

 Setting requirements

NR

 Without requirements for the range and input setting (preset - Pt100, three-wire connection of sensor, 0 to 100 °C)

QR

 Range and other parameters setting according to configuration sheet DB2298

Code

 Calibration

KPP5

 Transmitter calibration in five points evenly distributed in setting range

Kód

 Optional version

EI1

 Intrinsically safe version (Ex) II 1G Ex ia IIC T4-T6 Ga, (Ex) II 1D Ex ia IIIC T106°C Da (only for version P5311 H1x)

EN2

 Non-incendive design (Ex) II 3G Ex nA IIC T4 Gc

Code

 Optional accessories

LHPWinCom

 Set of configuration program LHPWinConf (CZ+EN) for PC and modem HARTMod

LHPConf

HARTConf

 HART-USB modem and field communicator for LHP and HART transmitters, function of transmitter supply
 supplied from USB or inbuilt accumulator, charged from USB

HARTMod

 Miniature HART modem with galvanic isolation

USB-RS232C

 Communication interface for to USB port of the PC

PT1000A

 Compensation resistor Pt1000 (-30 to +150 °C) for external compensation of thermocouple

S51

 Box for wall mounting of one transmitter to explosive atmosphere (IP 68)
 (Ex) II 2G Ex d IIC T6, T5 Gb + (Ex) II 2D Ex t IIIC T50/60/80°C Db (2 cable glands KMEx have to be ordered)

S52

  Box for wall mounting of one transmitter with LED display to explosive atmosphere (IP 68)
 (Ex) II 2G Ex d IIC T6, T5 Gb + (Ex) II 2D Ex t IIIC T50/60/80°C Db (2 cable glands KMEx have to be ordered)

S54

 Wall mounted box (100x100x58 mm), housing IP 65 (for H1x versions, not for EI1, EN2) 

1)

S55

 Wall mounted box (170x145x85 mm), housing IP 55 (for L1x versions, not for EI1, EN2) 

2)

S56

 Wall mounted box (100x100x58 mm), housing IP 65 (for H1x versions, not for EI1, EN2) 

3)

VH1

 Cap for head form B for transmitter mounting (for H1x versions)

APT1

 Adapter for flat head

KME1

 Cable outlet, nickel silver, Ex d, M20x1.5, IP 68, for fixed assembly cable with diameter 4 to 8.5 mm

KME2

 Cable outlet, nickel silver, Ex d, M20x1.5, IP 68, for fixed assembly cable with diameter 6 to 12 mm

KME3

 Cable outlet, stainless steel, Ex d, M20x1.5, IP 68, for fixed assembly cable with diameter 4 to 8 mm

KME5

 Cable outlet, polyamide, Ex ie, M20x1.5, IP 68, for fixed assembly cable with diameter 5 to 9 mm, operating temperature -20 to +95 °C

KME6

 Cable outlet, polyamide, Ex ie, M20x1.5, IP 68, for fixed assembly cable with diameter 6.5 to 12 mm, operating temperature -20 to +95 °C

3-year warranty 

       Example of order:  P5311  H11  QR

For code QR configuration sheet DB2298 is required to the order. 

• ... Ex stock version               ° ... Marked version can be dispatched up to 5 working days (with calibration up to two weeks)

1)

 … Possibility of installing one transmitter           

           2)

 … Possibility of installing up to three transmitters

3)

 … Possibility of installing two transmitters

 Field configurator for LHP transmitters, function of transmitter supply, without charging

°

°

7. Ordering information

7.1 Ordering table

Summary of Contents for P5310

Page 1: ...www jsp sk This document applies to serial numbers 10090000 and higher One type of transmitter for all common resistance and thermocouple sensors Linearized output signal 4 to 20 mA Accuracy from 0 1...

Page 2: ...4 Installation operation and maintenance 4 1 Installation and commissioning 6 4 2 Description of setting and configuration using the communicator LHPWinCom 7 4 3 Description of setting and configurati...

Page 3: ...e cover and provided with an identification label with a mark of the output control The product must not be exposed to direct rain vibrations and shocks during transport 1 5 Storage The products shall...

Page 4: ...minal block temperature or by the entered constant temperature The inner sensor guarantees maximum accuracy and stability of cold junction temperature measurement If required compensation using an ext...

Page 5: ...5 Low Cost Programmable Transmitters P5310 P5311 with LHP Communication 3 3 Dimensional drawings Version P531x H1x Version P531x L1x 3 4 Block diagram...

Page 6: ...ctrostatic charging Such case may be a metal temperature sensor head or a suitable metal installation box if it does not contain magnesium nor titanium During installation it is also necessary to resp...

Page 7: ...the input quantity The fixed output mode can be closed by the program button or by disconnecting of the transmitter power supply Transmitters in version EI1 or EN2 Ex version can be set up using the c...

Page 8: ...0 to 400 C IEC 584 1 thermocouple B 100 to 1800 C IEC 584 1 thermocouple E 200 to 950 C IEC 584 1 thermocouple L 200 to 900 C DIN 43710 thermocouple C 0 to 2300 C N I S T Monograph 175 range can be se...

Page 9: ...esponding temperature 10 C Range 0 to 4000 Ohm 0 1 SR or 0 8 Ohm or corresponding temperature 10 C Range 15 to 70 mV 0 1 SR or 0 02 mV or corresponding temperature 10 C the greatest value is valid Lon...

Page 10: ...RTMod Miniature HART modem with galvanic isolation USB RS232C Communication interface for to USB port of the PC PT1000A Compensation resistor Pt1000 30 to 150 C for external compensation of thermocoup...

Page 11: ...JSP Industrial Controls JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...