JSP P5310 Manual Download Page 1

MANUAL

P5310, P5311

Low-Cost Programmable Transmitters

with LHP Communication

Transmitters - NB0824EN-2 - 2016/04

JSP Industrial Controls

JSP, s.r.o. 

PHONE / FAX 

 

JSP Slovakia s.r.o. 

PHONE / FAX 

Raisova 547 

+420 493 760 811 

[email protected] 

Karloveská 63 

+421 2 6030 1080 

[email protected] 

CZ-506 01 Jičín 

+420 493 760 820 

www.jsp.cz 

SK-841 04 Bratislava 

+421 2 6030 1089 

www.jsp.sk 

This document applies to serial numbers 10090000 and higher. 

• One type of transmitter for all common resistance 
  and thermocouple sensors
• Linearized output signal 4 to 20 mA
• Accuracy from 0.1 % for ranges down to 1/5 
  of the basic range
• Span adjustability from 1 % to 100 % 
  of the basic range

• Galvanic isolation of input from output 
  1000 V AC (P5311)
• Adjustability by program LHPWinConf 
  and standard HART modem or by field  
  configurator LHPConf (HARTConf) 
• High immunity against interference 
  (industrial environment)
• Intrinsically safe version 

 II 1GD 

Summary of Contents for P5310

Page 1: ...www jsp sk This document applies to serial numbers 10090000 and higher One type of transmitter for all common resistance and thermocouple sensors Linearized output signal 4 to 20 mA Accuracy from 0 1...

Page 2: ...4 Installation operation and maintenance 4 1 Installation and commissioning 6 4 2 Description of setting and configuration using the communicator LHPWinCom 7 4 3 Description of setting and configurati...

Page 3: ...e cover and provided with an identification label with a mark of the output control The product must not be exposed to direct rain vibrations and shocks during transport 1 5 Storage The products shall...

Page 4: ...minal block temperature or by the entered constant temperature The inner sensor guarantees maximum accuracy and stability of cold junction temperature measurement If required compensation using an ext...

Page 5: ...5 Low Cost Programmable Transmitters P5310 P5311 with LHP Communication 3 3 Dimensional drawings Version P531x H1x Version P531x L1x 3 4 Block diagram...

Page 6: ...ctrostatic charging Such case may be a metal temperature sensor head or a suitable metal installation box if it does not contain magnesium nor titanium During installation it is also necessary to resp...

Page 7: ...the input quantity The fixed output mode can be closed by the program button or by disconnecting of the transmitter power supply Transmitters in version EI1 or EN2 Ex version can be set up using the c...

Page 8: ...0 to 400 C IEC 584 1 thermocouple B 100 to 1800 C IEC 584 1 thermocouple E 200 to 950 C IEC 584 1 thermocouple L 200 to 900 C DIN 43710 thermocouple C 0 to 2300 C N I S T Monograph 175 range can be se...

Page 9: ...esponding temperature 10 C Range 0 to 4000 Ohm 0 1 SR or 0 8 Ohm or corresponding temperature 10 C Range 15 to 70 mV 0 1 SR or 0 02 mV or corresponding temperature 10 C the greatest value is valid Lon...

Page 10: ...RTMod Miniature HART modem with galvanic isolation USB RS232C Communication interface for to USB port of the PC PT1000A Compensation resistor Pt1000 30 to 150 C for external compensation of thermocoup...

Page 11: ...JSP Industrial Controls JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Reviews: