3-3
1
General
The technical specification in this section deals with the JLN-900 system, including the
Transducer, Electronics unit, Log Processing Unit LPU2 and connected Display units.
Operating performance limits like inaccuracies or certain measurement criteria are set by the
speed sensors, i.e. the combination Transducer/Electronics unit.
2
Performance
The performance limits defined here are met when the log system is operating within the
environmental conditions described in this section and if calibration is correctly done.
2.1 Principle of operation
Log measures acoustic correlation using vertical beams. The log system uses two different
sensors, measuring Speed Through the Water (STW) and Speed Over the Ground (SOG)
simultaneously and independently.
2.1.1 STW (Speed Through the Water = relative speed)
Frequencies:
In the range 3.8 – 4.2 MHz
Speed is measured in a water volume 120–140 mm from the surface of the transducer.
Depth requirement: greater or equal to 3 m beneath the transducer.
Speed range:
+/-50 knots sensed Speed Through the Water.
2.1.2 SOG (Speed Over the Ground = true speed)
Frequency:
150 kHz
Depth requirement: greater or equal to 2 m beneath the transducer.
Depth range:
nominally 2 - 250 m below transducer.
Speed range:
40 knots in any direction.
2.2 Accuracy of measurement
2.2.1 STW
Speed error relative to sensed water speed:
0.1 knot or 1 %, whichever is greater.
Distance error relative to travelled distance (through the water):
1 %.
2.2.2 SOG
The SOG measurement system operates in different modes resulting in different accuracy of
the measurement. The "Normal mode" provides better accuracy and is active when the speed
and depth product (metres * knots) is above 67. The "Interpolation mode" is active when this
condition is not met resulting in a lower accuracy.
Normal mode:
0.1 knot or 1 %, whichever is greater.
Interpolation mode:
0.2 knots or 2 %, whichever is greater.
Distance error will improve with distance due to averaging positive and negative
instantaneous errors. Therefore, the error limit, expressed as a percentage of the travelled
distance, will decrease with increased accumulated distance.
Summary of Contents for JLN-900
Page 2: ......
Page 12: ...x This page is intentionally blank ...
Page 17: ...2 1 JLN 900 Technical Description ...
Page 23: ...2 7 sigbel ...
Page 30: ...2 14 This page is intentionally blank ...
Page 31: ...3 1 JLN 900 Technical Specification ...
Page 38: ...3 8 This page is intentionally blank ...
Page 39: ...4 1 JLN 900 Installation of Transducer and Bottom Parts ...
Page 59: ...4 21 Transducer and Valve Cover mounted Sea Valve fully opened ...
Page 63: ...4 25 Fig 1 3 Aligning Transducer Connecting Tube ...
Page 76: ...4 38 Mounting Sea Valve on Upper Flange DB ...
Page 81: ...4 43 Gasket Seal 2 ...
Page 83: ...4 45 Transducer and Valve Cover mounted Sea Valve fully opened ...
Page 86: ...4 48 Tube Bracket in its final position with Transducer flush seated ...
Page 88: ...4 50 Fig 2 5 Aligning Transducer Connecting Tube ...
Page 92: ...4 54 This page is intentionally blank ...
Page 93: ...5 1 JLN 900 Installation of NJC 80 Sig Processor ...
Page 150: ...6 50 This page is intentionally blank ...
Page 151: ...7 1 JLN 900 Display Technical Description ...
Page 167: ...7 17 No Name Default setting Function SD 4 2 SD 4 3 SD 4 4 there are remote systems connected ...
Page 179: ...8 1 JLN 900 Analog Display Technical Manual ...
Page 183: ...8 5 2 1 Main Dimensions NWW 828 Analog Display ...
Page 184: ...8 6 2 2 Dimmer Potentiometer connection Analog Display ...
Page 186: ...8 8 This page is intentionally blank ...
Page 187: ...9 1 JLN 900 Menu System ...
Page 208: ...9 22 This page is intentionally blank ...
Page 209: ...10 1 JLN 900 WATER TRACK Technical Manual including Menu system ...
Page 233: ...11 1 JLN 900 IEC 61162 NMEA 0183 User Guide ...
Page 254: ...11 22 This page is intentionally blank ...
Page 255: ...12 1 JLN 900 Harbour Acceptance Test ...
Page 266: ...12 12 This page is intentionally blank ...
Page 267: ...13 1 JLN 900 Calibration and Sea Acceptance Test ...
Page 280: ...13 14 This page is intentionally blank ...
Page 281: ...JLN 900 system drawings 14 1 ...
Page 289: ...CFT 780 4 TRANSDUCER 40m 14 9 ...
Page 290: ...NKF 980 Sea Valve 14 10 ...
Page 291: ...NKF 980 Sea Valve 14 11 ...
Page 292: ...NWW 82 MAIN DISPLAY 14 12 ...
Page 293: ...DISPLAY 3 1 87 14 13 ...
Page 294: ...NCM 1080 DIMMER UNIT 14 14 ...
Page 295: ...15 1 JLN 900 Description labels and drawings ...
Page 300: ...15 6 This page is intentionally blank ...
Page 301: ...16 1 Annex JLN 900 Speed Log System Manual ...
Page 302: ...16 2 Annex Table of contents ANNEX I EQUIPMENT RECYCLING 3 ANNEX II ENERGY SAVING 5 ...
Page 306: ...16 6 This page is intentionally blank ...
Page 307: ......