JOYTECH DBP-6277B Owner'S Manual Download Page 8

28

Maintenance

4.  Cuff Cleaning and Disinfection: 
    A) Spread the cuff (skin-contact surface) upwards onto a clean table. Use a damp clean cloth  
         (water-based) to wipe the skin-contact surface with a force.
    B) Soak the cloth clean with drinking water and wring it dry. Repeat A) with the damp cloth  
         (water-based) for 3 times. 
    C) Apply 70%-80% alcohol to a new cloth (or 75%  alcohol cotton-ball), use it to 
        wipe the skin-contact surface with a force. Then soak the cloth with the alcohol again
        (or change a new 75% alcohol  cotton-ball), repeat the disinfection procedure  for 3 times. 
    D

)

When

 

the

 

disinfection

 

towards

 

the

 

skin

-

contactsurface is

 

finished

,

wipe

 

thenon

-

skin

 

        contact surface

 

with

 

a

 

cloth (alcohol-based) or alcohol cotton-ball

 

thoroughly

 

for

 

        3 times.
    E

)

Leave

 

the

 

cuff

 

naturally

 

dry

,

then

 

it

 

is

 

ready

 

for

 

reuse

.

    

Notice: Do not soak in water or splash water on it.

5.  Do not use petrol, thinners or similar solvents.

6.  Remove batteries when not in operation for an extended period of time.

7.  Do not disassemble product.

8.  It is recommended the performance should be checked every 2 years.
9. Expected service life: Approximately three years at 10 tests per day.
10.No service and maintenance while it is in use and maintenance only be performed by service
      personnel. Service and maintenance require parts, repair, technical support will  be provided.

Maintenance

27

1.  Avoid dropping, slamming, or throwing the unit.

2.  Avoid extreme temperatures.  Do not expose unit directly under sunshine.

3.  When cleaning the unit, use a soft fabric and lightly wipe with mild detergent.

     Use a damp cloth to remove dirt and excess detergent.

30

29

Specifications

Specifications

Product Description

Model

Display

Measurement Method 

Pressurization

Memory

Function

Power Source

Battery Life 

Unit Weight

Unit Dimensions

Cuff Circumference

Oscillometric Method

Arm-type Fully Automatic Blood Pressure Monitor 

DBP-6277B 

LCD Digital Display   Size:83.1mm

×

53.1mm (3.27" x 2.09")

2x60 Memories in Two Groups with Date and Time

Irregular Heartbeat Detection

WHO Classification Indicator

Low Battery Detection

Automatic Power-Off

Voice

3 AAA batteries or  Medical AC Aadapter (DC5.0V, 1000mA)
(recommended, not provided)

Approximately 2 months at 3 tests per day

Approx.213g (7.51 oz.) (excluding battery)

Approx.149.8 x 80.4 x 45.7mm (5.90

"

 x 3.17

"

 x 1.80

"

 )(L x W x H)

Approx.135 (W) x 485(L) mm 
(Medium cuff: Fits arm circumference 22-36 cm)

Operating Environment 

                       Humidity

Temperature 

1

 ~ 40

 (50

~104

)

0

15% ~ 93%RH

Pressure 

800hPa~1060hPa

Automatic Pressurization 

Measurement Range

                    Pulse

Systolic Pressure

Pulse

60mmHg

2

60

mmHg

 30 ~ 180 Beats/Minute

±

5%

Diastolic Pressure

30mmHg

20

0

mmHg

Pressure

0mmHg

299mmHg

Pressure

±

3mmHg

Backlight

Last 3 Tests Average

Bluetooth

Classification

Ingress Protection 
rating

Battery Shelf life

 Battery Storage 
 Temperature

Internal Powered Equipment,Type BF         , Cuff is the Applied Part

IP 20,Indoor Used Only

60 months

-25

~55

 (-13

~131

)

Storage Environment

              Humidity

        Temperature 

-25

~55

 (-13

~131

)

93% RH

Transport Environment

              Humidity

        Temperature 

-25

~55

 (-13

~131

)

93% RH

Bluetooth

            Version

      Modulation Type 

GFSK

5.0.1 BT Signal mode

            Operation frequency

2

.

4GHz

(

2400

~

2483

.

5MHz

)

            Antenna gain

0.5   dBi

This Blood Pressure Monitor complies with the European regulations and bears the
CE mark“CE 0197”.This blood pressure monitor also complies with mainly
following standards
(included but not limited):
Safety standard:
EN 60601-1 Medical electrical equipment part 1: General requirements for safety
EMC standard:
EN 60601-1-2 Medical Electrical Equipment -- Part 1-2: General Requirements For Basic 
Safety And Essential Performance -- Collateral Standard: Electromagnetic Disturbances –
 Requirements And Tests. 
Performance standards:
IEC80601-2-30, Medical electrical equipment – Part 2-30: Particular requirements for the 
basic safety and essential performance of automated non-invasive sphygmomanometers.   
EN 1060-3 Non-invasive sphygmomanometers - Supplementary requirements for
electromechanical blood pressure measuring systems.
ISO 81060-2, non-invasive sphygmomanometers - part 2: clinical validation of automated 
measurement type.

Specifications are subject to change without notice.

            Bandwidth

2.0   MHz

Summary of Contents for DBP-6277B

Page 1: ...le Operation 1 Do not drop the unit Protect it from sudden jars or shocks 2 Do not insert foreign objects into any openings 3 Do not attempt to disassemble the unit 4 Do not crush the pressure cuff 5...

Page 2: ...ambulance or helicopter 30 Contains small parts that may cause a chocking hazard if swallowed by infants 31 Please align the polarities of each battery with the ve and ve signs imprinted on the batte...

Page 3: ...everal minutes prior to testing Sit down in a quietplace comfortably back and arm support on a desk or table withyour legs uncrossed your arm resting on a firm and your feet flat on the floor See Figu...

Page 4: ...es it will automatically save all information and shut off Unit Operation System Settings With power off press SET button to activate System Settings The Memory Group icon flashes 1 Select Memory Grou...

Page 5: ...memory can be viewed by pressing and holding the MEM button Upon activating test results you can press the MEM button to scroll through all test results stored in memory With power off press the MEM...

Page 6: ...GFSK Antenna gain 0 5dBi Troubleshooting Problem Solution displayed Connection failure Data is not being transmitted Cuff is too tight or not properly positioned on the arm Firmly reposition cuff app...

Page 7: ...Many factors including diet stress cuff placement etc may affect an individual s blood pressure Q Should I apply the cuff to the left or right arm What is the difference A Either arm can be used when...

Page 8: ...ate and Time Irregular Heartbeat Detection WHO Classification Indicator Low Battery Detection Automatic Power Off Voice 3 AAA batteries or Medical AC Aadapter DC5 0V 1000mA recommended not provided Ap...

Page 9: ...y 50 60 Hz magnetic field IEC 61000 4 8 30 A m 50Hz or 60Hz Power frequency magnetic fields should be at levels charactertic of a typical location in a typical comme rcial or hospital environment 30 A...

Page 10: ...advice Pressure calibration will be carried out when this product leaves the factory Patients can use the method described in the section Verify Manometer Pressure Accuracy to verify the accuracy If...

Reviews: