JOYTECH DBP-6277B Owner'S Manual Download Page 4

13

12

14

Unit Operation 

Unit Operation 

Unit Operation 

Applying the Arm Cuff

1.  Firmly insert air plug into opening located on behind side of monitor unit.  

2.  With sticky nylon section facing outward, insert end of cuff underneath metal ring 

     of cuff  

3.  Fasten cuff about 

above the elbow joint.  For best results apply cuff to 

     bare arm and keep level with heart while testing

.

1-2cm (0.4-0.8'') 

.

3. Time Format setting
     Press 

 SET 

button again to set the time fornat setting mode.Set the time format 

     by adjusting the

MEM

 button. EU means European Time US means U.S Time.

7.  Saved Settings

6.Volume Setting
Press "SET" button to enter volume setting mode. Set the voice volume by adjusting
the "MEM" button . There are six volume levels.

     While in any setting mode, press " START/STOP " button to turn the unit off.  All 
     information will be saved.  

Note:  If unit is left on and not in use for 3 minutes, it will automatically save all information 

            and shut off.

Unit Operation 

System Settings

With power off, press "SET" button to activate System Settings.  The Memory Group icon 

flashes.

1.  Select Memory Group 

     While in the System Setting mode, you may accumulate test  results into 2 different 

     groups.  This allows multiple users to save individual test results (up to 150 memories 

     per group.)  Press " MEM "  button to choose a group setting.  Test results will 

     automatically store in each selected group.

2.  Time/Date setting
     Press

SET

 button again to set the Time/Date mode. Set the year first by adjusting 

     the 

MEM

 button.

     Press

SET

 button again to confirm current month. Continue setting the date, hour 

     and minute in the same way. Every time the 

SET

 button is pressed, it will lock 

     in your selection and continue in succession ( month,day,hour, minute,12/24 hours)

11

AM

AM

5.Voice Setting
Press "SET" button to enter voice setting mode. Set voice format ON or OFF by
pressing the "MEM" button.

4.Unit Setting
Press "SET" button to enter unit setting mode. Set format bypressing the "MEM" button.

mmHg 

Summary of Contents for DBP-6277B

Page 1: ...le Operation 1 Do not drop the unit Protect it from sudden jars or shocks 2 Do not insert foreign objects into any openings 3 Do not attempt to disassemble the unit 4 Do not crush the pressure cuff 5...

Page 2: ...ambulance or helicopter 30 Contains small parts that may cause a chocking hazard if swallowed by infants 31 Please align the polarities of each battery with the ve and ve signs imprinted on the batte...

Page 3: ...everal minutes prior to testing Sit down in a quietplace comfortably back and arm support on a desk or table withyour legs uncrossed your arm resting on a firm and your feet flat on the floor See Figu...

Page 4: ...es it will automatically save all information and shut off Unit Operation System Settings With power off press SET button to activate System Settings The Memory Group icon flashes 1 Select Memory Grou...

Page 5: ...memory can be viewed by pressing and holding the MEM button Upon activating test results you can press the MEM button to scroll through all test results stored in memory With power off press the MEM...

Page 6: ...GFSK Antenna gain 0 5dBi Troubleshooting Problem Solution displayed Connection failure Data is not being transmitted Cuff is too tight or not properly positioned on the arm Firmly reposition cuff app...

Page 7: ...Many factors including diet stress cuff placement etc may affect an individual s blood pressure Q Should I apply the cuff to the left or right arm What is the difference A Either arm can be used when...

Page 8: ...ate and Time Irregular Heartbeat Detection WHO Classification Indicator Low Battery Detection Automatic Power Off Voice 3 AAA batteries or Medical AC Aadapter DC5 0V 1000mA recommended not provided Ap...

Page 9: ...y 50 60 Hz magnetic field IEC 61000 4 8 30 A m 50Hz or 60Hz Power frequency magnetic fields should be at levels charactertic of a typical location in a typical comme rcial or hospital environment 30 A...

Page 10: ...advice Pressure calibration will be carried out when this product leaves the factory Patients can use the method described in the section Verify Manometer Pressure Accuracy to verify the accuracy If...