2.  Testing

      After cuff inflation, air will slowly rise as indicated by the corresponding cuff pressure 

      value.  A flashing "         " will appear simultaneously on screen signaling heart beat 

      detection. 

Note:  Keep relaxed during testing.  Avoid speaking or moving body parts.

17

16

18

Unit Operation 

Unit Operation 

Unit Operation 

3.  Result Display 

     The screen will display measurements for systolic and diastolic blood pressure with voice 

     broadcast.  A indicator representing the current measurement will appear next to the 

     corresponding WHO Classification.

Irregular Heartbeat Indicator

If the monitor detects an irregular heart rhythm two or more times during the measuring 

process, the Irregular Heartbeat Symbol "        "appears on screen along with 

measurement results.  Irregular heartbeat rhythm is defined as rhythm that is either 25% 

slower or faster than the average rhythm detected while measuring systolic blood pressure 

and diastolic blood pressure.  Consult your physician if the Irregular Heartbeat Symbol 

"        " frequently appears with your test results.

Power Off

     

     turn off the power itself about 3 minutes  no operation in any mode.

The " START/STOP " button can be pressed to turn off the unit in any mode.  The unit can 

Note: Refer to Page 23~24 for detail WHO Blood Pressure 

 

Classification Information.

Safety Precaution: If pressure in arm cuff becomes too extreme while testing, 

press the " START/STOP " button to turn power off.  The cuff pressure will rapidly 

dissipate once the unit is off.

Unit Operation 

15

 Last 3 Tests Average

You may check past test results by  using the "MEM" button. The 
most recent test result and oldest test result in memory can be viewed by pressing
and holding the "MEM" button. Upon activating test results. you can press the "MEM" 
button to scroll through all test results stored in memory. 

With power off

press the "MEM" button to activate screen display. After the unit performs 

a self-diagnosis ,the screen will display the average test results from the last 3 readings 
of the last group used. The "AVG" symbol will appear along with the corresponding 
WHO Blood Pressure Indicator. The Memory Check mode can be accessed by
pressing "MEM" button. To check the average results from other groups, select the 
desired  group first prior to activating "SET" button in the off position.(See "Select 
Memory Group" on Page 11)

Memory Check 

IHB

IHB

Note:  Do not insert air plug into opening located on right side of monitor unit.  

            This opening is designed for an optional power supply only.

1-

2c

''

(0

.4

-0

.8

Testing

1.  Power On

     Press and hold "START/STOP" button to turn the unit on.  The LCD screen will appear for one

     second as unit performs a quick diagnosis.  A voice tone will indicate when unit is ready for

     testing. 

Note:  Unit will not function if residual air from previous testing is present in cuff.  

            The LCD will flash "        " until pressure is stabilized.   

PUL

/

min

OK

Bluetooth

SMART

AM

PM

Fast

A F

Slow

IHB

ECG

BP

mmHg 

OK

AM

BP

mmHg 

OK

PUL

/

min

Bluetooth

SMART

AM

BP

mmHg 

OK

PUL

/

min

Bluetooth

SMART

AM

BP

mmHg 

AM

BP

PUL

/

min

Bluetooth

SMART

AM

BP

mmHg 

If there is arm movement during the measurement, "             " may be shown.  Indicates that

it may lead to abnormal accurate measurement results. At this time,the LCD will display 

" Err".

Arm Shake Indicator

When starting the measurement, "             "will be displayed when the cuff is properly wound.

When the cuff is too loose, "             "will be displayed. At this time, please wear  the cuff correctly

and start measuring again.   

Cuff loose Indicator

OK

Summary of Contents for DBP-6277B

Page 1: ...le Operation 1 Do not drop the unit Protect it from sudden jars or shocks 2 Do not insert foreign objects into any openings 3 Do not attempt to disassemble the unit 4 Do not crush the pressure cuff 5...

Page 2: ...ambulance or helicopter 30 Contains small parts that may cause a chocking hazard if swallowed by infants 31 Please align the polarities of each battery with the ve and ve signs imprinted on the batte...

Page 3: ...everal minutes prior to testing Sit down in a quietplace comfortably back and arm support on a desk or table withyour legs uncrossed your arm resting on a firm and your feet flat on the floor See Figu...

Page 4: ...es it will automatically save all information and shut off Unit Operation System Settings With power off press SET button to activate System Settings The Memory Group icon flashes 1 Select Memory Grou...

Page 5: ...memory can be viewed by pressing and holding the MEM button Upon activating test results you can press the MEM button to scroll through all test results stored in memory With power off press the MEM...

Page 6: ...GFSK Antenna gain 0 5dBi Troubleshooting Problem Solution displayed Connection failure Data is not being transmitted Cuff is too tight or not properly positioned on the arm Firmly reposition cuff app...

Page 7: ...Many factors including diet stress cuff placement etc may affect an individual s blood pressure Q Should I apply the cuff to the left or right arm What is the difference A Either arm can be used when...

Page 8: ...ate and Time Irregular Heartbeat Detection WHO Classification Indicator Low Battery Detection Automatic Power Off Voice 3 AAA batteries or Medical AC Aadapter DC5 0V 1000mA recommended not provided Ap...

Page 9: ...y 50 60 Hz magnetic field IEC 61000 4 8 30 A m 50Hz or 60Hz Power frequency magnetic fields should be at levels charactertic of a typical location in a typical comme rcial or hospital environment 30 A...

Page 10: ...advice Pressure calibration will be carried out when this product leaves the factory Patients can use the method described in the section Verify Manometer Pressure Accuracy to verify the accuracy If...

Reviews: