JOYTECH DBP-6277B Owner'S Manual Download Page 1

Contents

Safety Notice  ...............................................................    02

Unit Illustration   .........................................................    06 

Important Testing Guidelines   .....................................    08

Quick Start   .................................................................   09

Unit Operation   ...........................................................    10

Blood Pressure Information   ........................................   23

Blood Pressure Q&A   ...................................................   26

Maintenance   ...............................................................   27

Specifications   .............................................................    29

Warranty   ....................................................................   31

Electromagnetic Compatibility Information    ..............    32

      Battery  Installation    ..................................................        10

      System  Settings    ........................................................          11 

      Applying  the  Arm  Cuff      .............................................        13

      Testing      .....................................................................        14

      Power  Off      ................................................................          17

   Memory Check 

   ...........................      18

      Memory  Deletion      .....................................................          19 

      Low  Battery  Indicator      .............................................            19

    Bluetooth  requirement  and  connection      ..............            20

      Troubleshooting      ...................................................            22

and Last 3 Test Average

Safety Notice

Model

   DBP-6277B

Arm Type

1

2

Owner's Manual

Arm-type Fully Automatic 

Digital Blood Pressure Monitor 

Thank you for purchasing the DBP-6277B Blood Pressure Monitor. The unit has been constructed 

using reliable circuitry and durable materials. Used properly, this unit will provide years of 

satisfactory use.

Measure blood pressure(systolic and diastolic)and pulse rate of adults and adolecents age 

12 through 21years of age. All functions can be used safely and values can be read out in one 

LCD DISPLAY. Measurement position is on adult upper arm only.

Blood pressure measurement determined with this device are equivalent to those obtained

by a trained observer using the cuff/ stethoscope auscultation method, within the limits

prescribed by the Recognized Consensus Standard (IEC 81060-2-30) for electronic

sphygmomanometers.

Precautions to Ensure Safe, Reliable Operation

1. Do not drop the unit. Protect it from sudden jars or shocks.

2. Do not insert foreign objects into any openings.

3. Do not attempt to disassemble the unit.

4. Do not crush the pressure cuff.

5. If the unit has been stored at temperatures below 0 oC, leave it in a warm place for

    about 15 minutes before using it. Otherwise, the cuff may not inflate properly.

6. If the unit has been stored at temperatures above 40 oC, leave it in a cool place for about 

    15 minutes before using it. Otherwise, the cuff may not inflate properly.

7. Do not store the unit in direct sunlight, high humidity or dust.

8.To avoid any possibility of accidental strangulation, keep this unit away from children

    and do not drape tubing around your neck.

9.Ensure that children do not use the instrument unsupervised; some parts are small 

   enough to be swallowed.

10.Some may get a skin irritation from the cuff taking frequent  readings over the course 

   of the day, but this irritation typically goes away on its own after the monitor is removed. 

The PATIENT is an intended OPERATOR

Document No.:

JDBP-7704-054

Contact Information

The lay operator or lay responsible or ganization should contact
 the manufacturer or the representative of manufacturer.
-for assistance,if needed,in setting up,using or maintaining 
the product,or
-to report unexpected operation or events.   
Manufactured by JOYTECH Healthcare Co.,Ltd.

Email: [email protected]
Telephone: +86-571-81957767
Fax: +86-571-81957750

No.365, Wuzhou Road,Yuhang Economic Development Zone,
Hangzhou City,311100 Zhejiang,China

Version

Z

Date of Issue

2020.06

Summary of Contents for DBP-6277B

Page 1: ...le Operation 1 Do not drop the unit Protect it from sudden jars or shocks 2 Do not insert foreign objects into any openings 3 Do not attempt to disassemble the unit 4 Do not crush the pressure cuff 5...

Page 2: ...ambulance or helicopter 30 Contains small parts that may cause a chocking hazard if swallowed by infants 31 Please align the polarities of each battery with the ve and ve signs imprinted on the batte...

Page 3: ...everal minutes prior to testing Sit down in a quietplace comfortably back and arm support on a desk or table withyour legs uncrossed your arm resting on a firm and your feet flat on the floor See Figu...

Page 4: ...es it will automatically save all information and shut off Unit Operation System Settings With power off press SET button to activate System Settings The Memory Group icon flashes 1 Select Memory Grou...

Page 5: ...memory can be viewed by pressing and holding the MEM button Upon activating test results you can press the MEM button to scroll through all test results stored in memory With power off press the MEM...

Page 6: ...GFSK Antenna gain 0 5dBi Troubleshooting Problem Solution displayed Connection failure Data is not being transmitted Cuff is too tight or not properly positioned on the arm Firmly reposition cuff app...

Page 7: ...Many factors including diet stress cuff placement etc may affect an individual s blood pressure Q Should I apply the cuff to the left or right arm What is the difference A Either arm can be used when...

Page 8: ...ate and Time Irregular Heartbeat Detection WHO Classification Indicator Low Battery Detection Automatic Power Off Voice 3 AAA batteries or Medical AC Aadapter DC5 0V 1000mA recommended not provided Ap...

Page 9: ...y 50 60 Hz magnetic field IEC 61000 4 8 30 A m 50Hz or 60Hz Power frequency magnetic fields should be at levels charactertic of a typical location in a typical comme rcial or hospital environment 30 A...

Page 10: ...advice Pressure calibration will be carried out when this product leaves the factory Patients can use the method described in the section Verify Manometer Pressure Accuracy to verify the accuracy If...

Reviews: