Jøtul GF 160 DV IPI Installation And Operation Instructions Manual Download Page 42

42

139894 GF 160 DV IPI   12/17

This warranty policy applies to gas products identified by the 

Jøtul trade name as set forth below.

A. LIMITED FIVE YEAR WARRANTY - Cast Iron, Steel Doors, 

Surround Components, Firebox:

Jøtul North America Inc. (JØTUL) warrants, to the original retail 

purchaser, that those components of the Jøtul Gas Stove or 

Fireplace specified above will be free of defects in material and 

workmanship for a period of five (5) years from the date of 

purchase.  This warranty is subject to the terms, exclusions and 

limitations set forth in the following text.

B.  LIMITED TWO YEAR WARRANTY - Burner, Ceramic Burner, 

BurnerTreatments, Firebox Panels:

 

JØTUL warrants, to the original retail purchaser, that those 

components of the Jøtul Gas Stove or Fireplace specified above 

will be free of defects in material and workmanship for a period 

of two (2) years from the date of purchase. 

Ceramic burners

 are 

warranted against functional defects for a period of two (2) 

years from the date of purchase.This warranty is subject to the 

terms, exclusions, and limitations set forth in the following text.

C. LIMITED TWO YEAR WARRANTY - Enamel Finish: 

JØTUL warrants, to the original retail purchaser, the enamel 

finish on cast iron components of the Jøtul Stove or Fireplace 

Insert specified above against peeling or fading for a period of 

two (2) years from the date of purchase. This warranty is subject 

to the terms, exclusions and limitations set forth below.

D. LIMITED ONE YEAR WARRANTY - Gas & Electrical Components 

(controls, plumbing, valve, blower)

JØTUL warrants, to the original retail purchaser, that those 

components of the Jøtul Gas Stove or Fireplace specified above 

will be free of defects in material and workmanship for a period 

of one (1) year from the date of purchase. This warranty is 

subject to the terms, exclusions, and limitations set forth in the 

following text.

JØTUL will repair or replace (including parts & labor), at its option, any 

of the above components determined by JØTUL to be covered by this 

warranty. You must, at your own expense, arrange to deliver or ship 

the component to an authorized Jøtul dealer and arrange for pickup 

or delivery of the component after repairs have been made.  If, upon 

inspection, JØTUL determines that the component is covered by this 

warranty, the repair or replacement will be made as set forth above. 

This warranty is not transferable and is extended only to, and is solely 

for the benefit of, the original retail purchaser of the Jøtul Gas Stove or 

Fireplace. This paragraph sets forth the sole remedy available under this 

warranty in the event of any defect in the Jøtul Gas Stove or Fireplace.

The warranty period for any replaced component will be the remaining 

unexpired portion of the warranty period for the original component.

Please retain your dated sales receipt in your records as proof of purchase.

 

EXCLUSIONS AND LIMITATIONS

NOTICE: This warranty is void if installation or service is performed 

by someone other than an authorized installer, service agency or gas 

supplier, or if installation is not in conformance with the installation and 

operating instructions contained in this owner’s manual or local and/

or national fire and building regulations.  A listing of local authorized 

installers, service agencies and gas suppliers can be obtained from the 

National Fireplace Institute at http://www.nficertified.org/.  

This warranty does not cover the following:

1)   Repair or replacement of parts that are subject to normal wear and 

tear during the warranty period or to parts that may require replacement 

in connection with normal maintenance. These parts include gaskets and 

glass (except to the extent such parts suffer damage from thermal stress).

2)  Damage due to incorrect installations not in conformance with the 

installation instructions contained in this owner’s manual or local and/or 

national fire and building regulations.

3)  Damage due to service performed by an installer, service agency or gas 

supplier, unless otherwise agreed to in writing by JØTUL. 

4)  Labor or other costs associated with the repair of gas controls, 

plumbing, burners, log set, or sheet metal firebox beyond the warranty 

period.

5)  Damage caused by unauthorized modification, use or repair.

6)  Damage to enameled surfaces caused by improper operation or 

misuse, including use that is not in conformance with the operating 

instructions contained in this owner’s manual. Such damage can typically 

be identified by bubbling, cracking, or discoloration of the enamel finish.

7)  Costs incurred by travel time and/or loss of service.

8)  Damage incurred while the Jøtul Gas Stove or Fireplace is in transit.

IN NO EVENT SHALL JØTUL, ITS PARENT COMPANY, SHAREHOLDERS, 

AFFILIATES, OFFICERS, EMPLOYEES, AGENTS OR REPRESENTATIVES BE 

LIABLE OR RESPONSIBLE TO YOU FOR ANY SPECIAL, INDIRECT, INCIDENTAL, 

CONSEQUENTIAL, PUNITIVE OR OTHER SIMILAR DAMAGES, INCLUDING, 

BUT NOT LIMITED TO, LOST PROFITS, LOST SALES, INJURY TO PERSON OR 

PROPERTY, OR DAMAGES TO A STRUCTURE OR ITS CONTENTS, ARISING 

UNDER ANY THEORY OF LAW WHATSOEVER.  ALL IMPLIED WARRANTIES, 

INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE, ARE LIMITED IN 

DURATION TO THE LENGTH OF THIS WRITTEN WARRANTY.  EXCEPT AS 

EXPRESSLY SET FORTH HEREIN, JØTUL MAKES NO ORAL, WRITTEN OR 

OTHER WARRANTY WITH RESPECT TO JØTUL GAS STOVES OR FIREPLACES.

Some states do not allow the exclusion or limitation of incidental 

or consequential damages, or limitations on the length of implied 

warranties.  Therefore, the above exclusions or limitations may not apply 

to you.  This warranty gives you specific legal rights, and you may have 

other rights, which vary from state to state. 

JØTUL reserves the right to discontinue, modify or change the materials used 

to produce the Jøtul Gas Stove or Fireplace.  JØTUL shall have the right to 

replace any defective component with substitute components determined by 

JØTUL to be of substantially equal quality and price. 

The dollar value of JØTUL’s liability for breach of this warranty shall be 

limited exclusively to the cost of furnishing a replacement component.  

JØTUL shall not in any event be liable for the cost of labor expended 

by others in connection with any defective component.  Any costs or 

expenses beyond those expressly assumed by JØTUL under the terms of 

this warranty shall be the sole responsibility of the owner(s) of the Jøtul 

Gas Stove or Fireplace.

No dealer, distributor, or other person is authorized to modify, augment, 

or extend this limited warranty on behalf of JØTUL.  NO MODIFICATION 

OR CHANGE TO THIS WARRANTY WILL BE EFFECTIVE UNLESS IT IS MADE IN 

A WRITTEN DOCUMENT MANUALLY SIGNED BY AN AUTHORIZED OFFICER 

OF JØTUL.

An authorized installer may have been provided with certain information 

related particularly to the Jøtul Gas Stove or Fireplace; however, no 

authorized installer or other person who may service the appliance is 

an agent of JØTUL.  No inference should be made that JØTUL has tested, 

certified, or otherwise pronounced any person as qualified to install or 

service the appliance.  JØTUL shall not be liable or otherwise responsible 

for any error or omission by a person installing or servicing a Jøtul Gas 

Stove or Fireplace.

If you believe your Jøtul Gas Stove or Fireplace is defective, you should 

contact your nearest authorized Jøtul dealer, who will process a warranty 

claim.  IN ORDER TO QUALIFY FOR WARRANTY COVERAGE, JØTUL MUST 

RECEIVE NOTICE OF A POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE 

DATE THE DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE 

BEEN DISCOVERED.

This warranty is given by Jøtul North America, Inc.,  

55 Hutcherson Drive, Gorham, Maine 04038 USA 

18.  Jøtul Gas Product  

Warranty

Summary of Contents for GF 160 DV IPI

Page 1: ...and service must be performed by a qualified installer service agency or the gas supplier In the Commonwealth of Massachusetts a carbon monoxide CO detector shall be installed in the same room as the...

Page 2: ...t b Be either hard wired or battery powered or both and c Shall comply with NFPA 720 2005 Edition 3 A Product approved vent terminal must be used and if applicable a Product approved air intake must b...

Page 3: ...heck 23 14 Flame Picture Adjustment 24 15 Operation Guidelines 25 Manual Operation 26 Remote Control 27 30 16 Maintenance 31 Annual Cleaning 31 Glass Care Replacement 31 Safety Screen Replacement 33 B...

Page 4: ...t LP 158057 Rock Wool Embers 1 oz 157259 1 5v AA Alkaline Batteries 4 224109 Remote Control Transmitter 157495 Remote Transmitter Wall Bracket 223951BKP Door Adjustment Washers 3 117587 GF 160 DV IPI...

Page 5: ...ove the Glass Panel by pulling the two latch hooks out to disengage them from the glass frame Fig 2 2 Tilt the glass frame forward then lift it straight up and off of the stove 3 Remove the Miscellane...

Page 6: ...erous operation Verify operation after servicing 4 Safety Information Due to the high operating temperatures this appliance should be located out of traffic and away from furniture and draperies Maint...

Page 7: ...istant materials are considered combustible they are difficult to ignite but will burn Also fire rated sheet rock is considered combustible Floor Protection This appliance MAY NOT be installed directl...

Page 8: ...cove Ceiling Height from floor 69 1752 mm Alcove clearances are determined through testing in specific construction configurations which often result in greater clearances than an open stove installat...

Page 9: ...c Direct Vent Industrial Chimney Corp ExcelDirect Bernard Dalsin Mfg Pro Form Olympia Chimney Supply Inc Ventis Direct Vent Use parts of one manufacturer only DO NOT MIX VENT COMPONENTS FROM DIFFERENT...

Page 10: ...ertical vent runs over 12 ft in uninsulated air space may require the stove be operated in CPI mode for best performance ALL VENTING MUST TERMINATE END WITHIN ONE OF THE DESIGNATED AREAS SET STOVE EXH...

Page 11: ...QUIRE THE APPLIANCE BE OPERATED IN CONTINUOUS PILOT MODE CPI TO ASSURE ADEQUATE DRAFT AND PROPER PERFORMANCE RE INSTALL THE TOP PLATE BEFORE CONNECTING VENT TO THE STOVE Horizontal Termination Any hor...

Page 12: ...h grade and building clearance requirements per local and national building codes Figure 6 7 Minimum vent required for horizontal termination Any horizontally terminated vent run must include a minimu...

Page 13: ...a height 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 3 ft 91 cm J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any o...

Page 14: ...TS OF THE CAN1 B149 1 AND 2 INSTALLATION CODE Fuel Conversion Procedure 1 Turn off gas supply to stove 2 Open the door and release the glass frame latches to remove the glass frame and open the firebo...

Page 15: ...d Red LP indicator Figure 7 3 Injector and Pilot conversion The LP shutter lock screw sets the minimum shutter opening for propane INSTALLER NOTE Pilot Shield is removed for PROPANE in a Minimum Vent...

Page 16: ...lt the burner assembly downward to engage the venturi tube with air shutter assembly BE CERTAIN THE BURNER IS LEVEL AND SECURELY ENGAGED WITH THE FRONT SUPPORTS ON THE FIREBOX FLOOR 10 Remove the Util...

Page 17: ...nstall the LP regulator motor using the new components included in that kit Connect the motor leads to Terminal M on the IFC See Fig 7 8 13 Reinstall the Control Compartment and Utility Panel Engage t...

Page 18: ...alternatives 14 Apply the identification labels to the stove where they can be seen by a service person Label A apply to the Lower Door Hinge Fig 7 8 Label B apply to the designated field on the stove...

Page 19: ...use at elevations above 2000 feet Check with your gas supplier before performing derate adjustment to the burner If the gas supplier does not derate fuels install High Altitude Adjustment Kit 158059...

Page 20: ...t a panel in place against the firebox wall and use a flat head screwdriver to pry the retainer tab down just enough to hold the panel snug in place 3 Repeat with the other side panel INSTALL FUEL OR...

Page 21: ...orner of the firebox as shown in fig 12 1 3 Left Log Engage the hole in the charred end of the Left Log 3 with the Base Log pin and lean it up against the back corner of the firebox See figs 12 1 and...

Page 22: ...do not completely block gas flow through the ports in a single layer Also DO NOT OBSTRUCT THE AIR SPACE BETWEEN THE BURNER PERIMETER AND THE BURNER SKIRT See fig 12 4 Clear White Fire Glass 156815 Bl...

Page 23: ...LIFIED PROFESSIONAL SERVICE TECHNICIAN INITIAL FIRING PROCESS Heat curing the Stove Paint This appliance has been painted with the highest quality coating used in the hearth industry Manufacturers hav...

Page 24: ...the air inlet shutter has been set to provide optimal combustion efficiency under a variety of venting configurations The air shutter may be adjusted however to accommodate the conditions of your indi...

Page 25: ...er flammable liquids 5 This appliance can be operated with a continuously burning pilot flame Exercise caution when using household products containing combustible vapors 6 CAUTION DO NOT OPERATE THIS...

Page 26: ...n ignition device that lights the pilot automatically Do not try to light the pilot by hand 1 Set the Mode Switch to OFF See fig 15 1 2 Confirm the stove is connected to 120VAC house current 3 Mode Sw...

Page 27: ...decreases or steps down the fire intensity Conversely as room temperature cools the valve gradually increases flame intensity The overall result is more comfortable even heating that minimizes temper...

Page 28: ...temperature range and flame height MODE Key used to select the component to be controlled CPI IPI Burner and Accent Lamp The supplied Wall Mount Bracket can be used for convenient hand held transmitt...

Page 29: ...ot will ignite followed shortly by the burner A single beep from the Receiver will confirm reception of the command Turn off the Burner Press the ON OFF Key The display will show only the room tempera...

Page 30: ...l turn the Lamp OFF Child Safety Lock This function will lockout the Transmitter to prevent unsupervised operation To activate the Lock press the Mode key and UP Key at the same time Fig 15 17 To de a...

Page 31: ...ust and debris Vacuum more frequently if there are pets in the home Use a soft brush attachment and handle log set components carefully The pilot assembly and burner base should be inspected and clean...

Page 32: ...cated below the firebox floor and push the stem back far as it will travel See fig 7 1 page 15 4 Remove the Burner Lift the front of the burner base to disengage it from the support brackets and pull...

Page 33: ...screws and retainer brackets as shown in fig 16 4 The replacement screen and frame installs as a single unit using the original four brackets and screws 7 Install replacement side glass and gasket Wra...

Page 34: ...ng See fig 16 4 Depress the center release tab to open the battery access cover 3 Install four 1 5v AA batteries following the polarity orientation shown below and on the panel 4 Reconnect power to th...

Page 35: ...35 GF 160 DV IPI 12 17 Figure 17 1 GF 160 DV IPI Proflame 2 Wiring Schematic including Premium Upgrade components 17 Appendix PILOT 0584 922 0584 921 0584 920 0584 924...

Page 36: ...36 139894 GF 160 DV IPI 12 17 78 Figure 17 2 GF 160 DV IPI Firebox and Cast Iron Assembly...

Page 37: ...ire Strain Relief Heyco 7P 2 Large 36 22605092 Rear Cover Supply Lines Matte Black 37 158080 Glass Ceramic Side 5mm 197 INC Gasket 38 38 225961 Gasket Woven Tape 187 x 750 39 22595492 Retainer Side Gl...

Page 38: ...4 Proflame 2 IFC Control Board 11 158006 Replacement Proflame 2 Battery Box 12 226048 Controls Cover 13 226294 Rating Plate Bracket 14 22605992 Control Door Matte Black 15 118034 Bolt M6 x12 Button Hd...

Page 39: ...917 Screw 8 x 1 2 SM 7 9911 Bolt Hex Cap m6 x 45mm Blk 8 120004 Washer Fender 6 4mm ID x 18mm OD x 1 6mm 9 118267 Sleeve 375 OD x 312 OD x 1 50 10 22602892 Delay Door MB 11 226070 Gasket Delay Door 12...

Page 40: ...24 CFR PART 3280 THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS THAT IS INDICATED ON THE STOVE S RATING PLATE A GAS CONVERSION KIT IS PROVIDED WITH THE GF 160 DV IPI GAS STOVE THIS APPLIANCE MAY...

Page 41: ...41 GF 160 DV IPI 12 17 Burner Reference Flame Patterns Figure 17 7 Rock Set flame pattern Figure 17 8 Tumbled Stone flame pattern Figure 17 9 Fire Glass flame pattern...

Page 42: ...not in conformance with the installation instructions contained in this owner s manual or local and or national fire and building regulations 3 Damage due to service performed by an installer service...

Page 43: ...eplace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING 1 Set the thermostat to the lowest setting 2 Turn off al...

Page 44: ...tions December 2017 139894 Your stove has a unique serial number stamped on the rating plate which is hung on the back Please record the serial number in the space below You may also wish to attach yo...

Reviews: