Appendix A:

Alternate floor protection

All floor protection materials must be non-combustible ie. Metal, 
brick, stone, mineral fiber boards). Any combustible material may 
not be used.  

The easiest means of determining if a proposed alternate floor 
material meets requirements listed in this manual is to follow 
this procedure.

R-value = 

thermal 

resistance

K-value = 

thermal 

conductivity

C-value = 

thermal 

conductance

1.  Convert the specification to r-value;
 

a. 

If r-value is given, no conversion is needed.

 

b. 

If k-value is given with a required thickness (t) in inches: 

R=1/k X T.

 

c. 

If c-value is given: R=1/C.

2.    Determine the r-value of the proposed alternate floor 

protector.

 

a.  

Use the formula in step 1 to convert values not expressed 

as “R”.

 

b. 

For multiple layers, add r-values of each layer to 

determine overall r-value.

3.  If the overall R-value of the sustem is greater than the 

R-value of the specified floor protector, the alternate is 
acceptable.

Example:

The specified floor protector should be 3/4” thick material with a 
k-factor of 0.84. The proposed alternate is 4” brick with a c-factor 
of 1.25 over 1/8” mineral board witha k-factor of 0.29. 

Step A.

 

Use formula above to convert specifications to 
R-value.  R=1/k x t= 1/.84 x .75 = .893

Step B.

 

Calculate r of proposed system.

 

4” brick of c-1.25, therefore 

 

R brick = 1/c = 1/1.25 = 0.80

 

1/8” mineral board of K = 0.29 therefore 

 

R mineral board = 1/.29 x 0.125 = 0.431

 

Total R = R brick + R mineral board= 0.8 + 0.431=1.231

Step C.

 

Compare proposed system R = 1.231 to specified R of  
0.893.  Since R is greater than required, the system is 
acceptable.

Definitions:

Thermal conductance = 
 

C =    btu  

    W        

  

(Hr)(ft2)(f) 

(m2)(k)

Thermal conductivity =
 

K =    btu       =      W       = 

  (btu)

  

(Hr)(ft2)(f) 

(m2)(k) 

(hr)(ft)(f)

Thermal resistance = 
 

R =    btu  

(m2)(k)  = 

(btu)(inch)

  

(Hr)(ft2)(f) 

 

W (hr)(ft2)(f)

 

Partlist   Jøtul F 

602

 CB

Pos Description 

.........................................Dim./Spec.

Hot plate ........................................... 240 mm

Gasket ................................................ LD 360 Ø8.7x850

Screw, panhead ............................... M6x12 DIN 7985

4 Air 

deflector

5 Nut 

...................................................... M8

Gasket ................................................ LD 187-1 Ø4.8x600

7 Gasket 

................................................ V-125 

8x150

Spring for glass-door ..................... Ø7.6x13

Door vent baffle

10 

Screw, self thread ............................ M6 x 16

11 Flue 

outlet

12 Back 

plate

13 Side 

panel

14 Rivet 

................................................... Ø3x12

15 Rivet 

................................................... Ø2,4x4

16 Label
17 Label 

shield

18 

Cover for smoke outlet

19 

Countersunk screw  ........................ M6x16

20 Baffle 

plate

21 Air 

manifold

22 

Air chamber, complete

23 Air 

chamber

24 

Screw, collar head ........................... M6x10

25 

Screw, collar head ........................... M6x25

26 Rivet 

................................................... Ø8x16 

mm

27 Knob, 

wood

28 

Screw, filister head ......................... M6x70

29  Nut w/ collar .................................... M6
30 Door 

catch

31 Door 

handle

32 

Screw, cylinder head ....................... M6x30 DIN 84 S.krom.

33 

screw, collar head ............................ M 6x35

34 Insulating 

blanket 

.......................... 360x185

35 

Burnplate, side, with insulation

36 Burnplate, 

bottom

37 Insulating 

blanket 

.......................... 360x330

38 Screw, 

hex 

......................................... M6x25

39 Washer 

.............................................. Ø18x06,4x1.6

40 Top 

plate

41 Pin, 

door

42 

Glass door, complete incl. handle

44 Glass, 

ceramic 

.................................. 4x147x154

45 

Air slide vent

46  Front plate, complete
47 Front 

plate

48 Base 

plate

49  Legs, package of four
50  Leg, 1 pcs
51 

Heatshield - bottom

52 

Increaser ............................................ Ø 126xØ154 mm

53 Decorative 

top

54 Casing
55 Washer
56  Washer, black crom.

US/CAN

Summary of Contents for F 602 CB

Page 1: ... Operating Instructions 2 CA Installation et mode d emploi pour le Canada 13 Figures 24 Kindly save these instructions for future reference Ce document doit être conservé pendant toute la vie de l appareil Jøtul F 602 CB Manual Version P12 ...

Page 2: ...at regulations apply in your area The Jøtul F 602 CB has been tested and listed to ANSI UL 1482 UL 737 and ULC S627 by Intertek Testing Services Warnock Hersey of Middlet on Wisconsin Table of contents General information Possible hazards to avoid when using the Jøtul F 602 CB 2 1 0 Installation Safety notice 3 Top Exit or Rear Exit 3 Attaching the Legs 3 2 0 Plan Ahead Chimney connector Stove Pip...

Page 3: ...your Jøtul dealer Never burn trash of any kind in the stove Keep combustible materials far away from the stove Never modify the stove in any way Do not dry clothes over the stove since they could fall and ignite Use only seasoned wood in your stove Never use fireplace coal or synthetic logs that have not been approved for the stove Always wear protective gloves when adding fuel to the fire If you ...

Page 4: ...n Canada refer to CAN CGA B356 Before beginning the installation contact local building officials to make sure the proposed pass through method meets local building code requirements A commonly used method to pass through a wall directly to a masonry chimney requires removal of all combustible material from at least 12 around the entire chimney connector The space is then filled with at least 12 o...

Page 5: ... have at least 2 of clearance to the combustible structure A chimney outside the house must have at least 1 clearance to the combustible structure Fire stops must be installed at the spaces where the chimney passes through floors and or ceilings Remember that there must be air space around the chimney and that insulation must be 2 or more from the chimney A chimney wether masonry or prefabricated ...

Page 6: ...g 7 page 23 The floor protection must have a minimum R value of 47 Warning Never put any type of floor protection on top of carpeting 4 2 Alternate Floor Protection All floor protection materials must be non combustible i e metals brick stone mineral fiber boards etc Any organic materials i e plastics wood paper products etc are combustible and must not be used The floor protector specified may in...

Page 7: ...ncies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods Do not burn Coal Garbage Cardboard Treated or painted Wood Solvents Treated or painted Wood Chemical Chimney Cleaners Colored Paper Any synthetic fuel or logs that have not been approved for wood stoves Burning treated wood garbage solvents colored pape...

Page 8: ...or will diminish with each fire and eventually disappear Opening a window or door near the stove will help provide additional ventilation and reduce the odor 5 5 Building a Fire Agoodfirewillefficientlyutilizeyourfuel keep theglassin the door clean keep emissions and creosote to an absolute minimum require less work and be very predictable A Good Foundation Make sure the air control handle is full...

Page 9: ...dy Any creosote which might deposit on the glass will burn off during the next hot fire Never clean the glass while it is hot and never use any abrasive materials to clean the glass Cool water and a soft cloth or paper towel are usually all that is required Rinse thoroughly with clean water after washing and dry completely before burning your stove 6 2 Glass Replacement To prevent cracking of the ...

Page 10: ...kettles or pots can damage the enamel 6 4 Gaskets Check the door and window gaskets for tightness To check the front door gasket put a dollar bill halfway into the stove close and latch the door and try pulling the dollar out lf it can be removed easily the seal is too loose Check several spots around the door To replace the gasket scrape out all old gasket material and gasket cement Spread a 1 8 ...

Page 11: ...he component is covered by this warranty the repair or replacement will be made as set forth above This warranty is not transferable and is extended only to and is solely for the benefit of the original retail purchaser of the Jøtul or Scan Stove or Fireplace Insert This paragraph sets forth the sole remedy available under this warranty in the event of any defect in the Jøtul Scan Stove or Firepla...

Page 12: ...omponents determined by JØTUL to be of substantially equal quality and price The dollar value of JØTUL s liability for breach of this warranty shall be limited exclusively to the cost of furnishing a replacement component JØTUL may at its discretion discharge all obligations by refunding the wholesale price of any defective part or appliance JØTUL shall in no event be liable for any special indire...

Page 13: ...le fonctionnement ou l entretien du poêle Jøtul F 602 CB veillez à suivre les directives du présent manuel Conservez les et tenez les à la disposition de toute personne susceptible de se servir de ce poêle Plusieurs régions des États Unis et du Canada requièrent un permis de construction pour l installation d un appareil de chauffage à combustible solide La norme canadienne CAN CSA ACNOR B 365 Cod...

Page 14: ...r usage dans les maisons mobiles 1 0 Installation Avis de sécurité L installation non appropriée de ce poêle à combustible solide risque de causer un incendie Assurez votre sécurité en respectant les directives d installation et consultez les autorités locales de la construction et de la prévention des incendiesausujet deslimitationset desexigencesrelatives aux inspections particulières à votre ré...

Page 15: ...ions devront être prises La norme CAN CSA ACNOR B 365 Code d installation pour appareils et équipement à combustible solide prévoit quatre méthodes à cet effet Avant de commencer votre installation renseignez vous auprès de vos autorités locales de la construction sur la méthode de traverse proposée pour votre poêle compatible avec les codes locaux de la construction La méthode la plus commune de ...

Page 16: ...m d épaisseur La cheminée doit être doublée d une chemise argileuse ou équivalente d au moins 1 1 2 cm et doit être installée au moyen de mortier réfractaire Un espace minimal d 1 1 4doit séparer la chemise du conduit de fumée du mur de la cheminée Le diamètre nominal préférable de la chemise argileuse de cheminée est de 20 1 4 x 20 1 4 cm il ne pourra en aucun cas dépasser un diamètre maximal 20 ...

Page 17: ...une surface incombustible dépassant chaque côté et l arrière de l appareil de 8 Aux USA la protection doit dépasser de 16 à l avant Au CANADA elle doit dépasser de 18 Cette protection doit aussi recouvrir la surface par dessous toutes sections horizontales de raccord de cheminée tuyau de poêle et doit s étaler sur au moins 5 cm au delà de chaque côté du tuyau Illustr 7 page 22 4 2 Alternante Prote...

Page 18: ...23 Notes 1 Renseignez vous auprès de votre concessionnaire sur les diminutions de dégagement de plafond avec protection 2 Si la largeur de I un des deux murs latéraux est supérieure à 61 cm le dégagement du mur latéral le plus large sera de 63 1 2 cm 5 0 Fonctionnement Avant depréparerunfeudansvotrenouveaupoêle veuillez lire attentivement le chapitre suivant 5 1 Ce poêle a été conçu uniquement pou...

Page 19: ...e brûlage sont requises Vous déterminerez les meilleurs réglages pour votre usage personnel au fur et à mesure que vous vous familiariserez avec votre poêle Le poêle est chaud pendant son fonctionnement Eloignez les enfants et ne gardez pas de vêtements ou de meubles à proximité Ne stockez pas de combustible à l intérieur des dégagements énumérés précédemment 5 4 Rodage du poêle Un poêle de fonte ...

Page 20: ...manation de monoxyde de carbone suivant les carburants par exemple le charbon le monoxyde de carbone est extrêmement dangereux Assurez vous que le poêle et la pièce bénéficient d une bonne ventilation 5 8 Retrait des cendres Le retrait des cendres est requis chaque jour ou deux pendant une saison de fonctionnement normal il est bien plus facile à effectuer lorsque le bois brûlé est calciné en char...

Page 21: ... du verre et au long des bords extérieurs Il vous faudra tordre le joint de sorte que I adhésif soit dirigé vers le verre Pressez ces morceaux fermement en position sur le verre Replacez la glissière de la commande d air les pattes de fixation supérieures et les vis Il est extrêmement important que les pattes soient serrées un peu à la fois et qu elles imitent le serrage des goujons d une roue d a...

Page 22: ...mplacement seront effectués comme précédemment spécifiés Cette garantie n est pas transférable et s applique uniquement à l acheteur initial du foyer encastrable ou du poêle Jøtul ou Scan Ce paragraphe établit le seul recours offert en vertu de la présente garantie en cas de défaillance quelconque d un poêle ou foyer encastrable Jøtul ou Scan La période de garantie pour tout composant remplacé ser...

Page 23: ...tériaux utilisés pour la fabrication des poêles ou des foyers encastrables Jøtul ou Scan JØTUL se réserve le droit de remplacer tout composant défectueux par des composants de remplacement que JØTUL juge de qualité et de prix quasiment égaux La valeur monétaire maximale que peut verser JØTUL en cas de violation de la présente garantie est limitée exclusivement aux coûts générés dans la fourniture ...

Page 24: ...m 380mm 305mm 205mm 205mm Connector Unprotected surface Protected surface NFPA 211 clearances pipe Vertical installation Vertical installation Single wall pipe 18 6 460mm 150mm Double wall pipe pipe mfgr listing pipe mfgr listing Connector Unprotected surface Protected surface NFPA 211 clearances pipe Horizontal installation Horizontal installation Single wall pipe 18 9 460mm 230mm Double wall pip...

Page 25: ... Pass through con struction 12 30 5 Brick from thimble to combustibles 12 Sill Support Thimble 5 8 1 6cm Fi reclay Liner or equivalent Fig 4 At least 3 feet 91 5 cm At least 2 feet 61 cm At least 10 feet 305 cm Fig 1 Fig 2 Measurements in cm for Canada Chimney Connector points toward stove Flue gas direction US CAN ...

Page 26: ...acent Combustible A B A 21 53 5cm B 13 5 34 5 cm Fig 8 A A B B C C A 13 33 5 cm B 20 1 4 51 5cm Fig 9 A B A 24 61 cm B 19 48 3cm Fig 10 Connector pipe must be flush with the inside of the flue tile Chimney Connector Pipe Thimble Flue Tile Fig 6 Measurements in cm for Canada US CAN Hearth protection Fig 7 A 8 20 cm B U S 16 41 cm B CAN 18 46 cm 2 5 cm 43 1 2 111 cm CAN 45 1 2 116 cm 28 1 2 73 cm A ...

Page 27: ...22 cm Fig 13 A Min 96 244 cm 1 B Max 24 61 cm 1 Alcove with rear heatshield Fig 15 A Min 96 244 cm B Max 48 122 cm C Min 41 104 cm D 1 2 5 cm Alcove with wall protection Measurements in cm for Canada Parallel installation with wall shield Wall shield Must be 27 wide and centered be hind the stove Must be 1 off the wall and 1 off the floor With single wall pipe the shield must be 49 high measured o...

Page 28: ...n Parallel installation in a corner with wall shield Fig 17 The wall shield must extend a mini mum of 7 178mm past the ash lip of the stove Wall shield Must be 1 off the wall and 1 off the floor With single wall pipe the shield must be 49 high measured off the floor With double wall pipe the shield must be 37 high measured off the floor Both shields MUST extend and join in the corner Combustible w...

Page 29: ...A 13 12 29 28 11 6O2 N 47 46 45 44 43 42 41 B B Snitt B B Section B B 18 27 10 40 19 26 33 48 49 C C Snitt C C Section C C 23 22 6 9 7 5 3 4 2 1 8 25 39 50 52 53 51 Part list Jøtul F 602 USA Jøtul AS Fredrikstad Norway Draw no 1 1233 P07 Date Jan 03 54 56 55 29 US CAN ...

Page 30: ... 0 125 0 431 Total R R brick R mineral board 0 8 0 431 1 231 Step C Compare proposed system R 1 231 to specified R of 0 893 Since R is greater than required the system is acceptable Definitions Thermal conductance C btu W Hr ft2 f m2 k Thermal conductivity K btu W btu Hr ft2 f m2 k hr ft f Thermal resistance R btu m2 k btu inch Hr ft2 f W hr ft2 f Partlist Jøtul F 602 CB Pos Description Dim Spec 1...

Page 31: ...31 ...

Page 32: ...nd as a result of Jøtul s vast experience dating back to when the company first started in 1853 Weappreciateyour trust inwelcomingourproduct intoyourhomeandinviteyourcomment and appraisal of our efforts to provide you with the finest in home hearth products Qualité Le système de contrôle de la qualité de Jøtul AS est conforme à la norme NS EN ISO 9001 relative à la conception à la fabrication et à...

Reviews: