3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are
fi
tted by a quali
fi
ed
installer (see www.jotul.com for a complete list of dealers).
Any modi
fi
cations to the product may result in the product
and safety features not functioning as intended. The same
applies to the installation of accessories or optional extras not
supplied by Jøtul. This may also be the case if parts that are
essential to the functioning and safety of the
fi
replace have
been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your
fi
replace. The following instructions must therefore be
followed:
• The minimum safety distances when installing and using
the
fi
replace are given in
fi
g. 1
. The speci
fi
ed distance to
fl
ammable materials, applies to this stove. The stove must
be installed with a CE approved
fl
ue. The distance of the
fl
ue pipe to combustible materials must also be observed.
• Ensure that furniture and other
fl
ammable materials are not
too close to the
fi
replace. Flammable materials should not
be placed within
min. 700 mm
of the
fi
replace.
• Allow
the
fi
re to burn out. Never extinguish the
fl
ames with
water.
• The
fi
replace becomes hot when lit and may cause burns
if touched.
• Only remove ash when the
fi
replace is cold. Ash can contain
hot embers and should therefore be placed in a non-
fl
ammable container.
• Ash should be placed outdoors or be emptied in a place
where it will not present a potential
fi
re hazard.
In case of chimney
fi
re:
• Close all hatches and vents.
• Keep
the
fi
rebox door closed.
• Call
the
fi
re service.
• Before use after a
fi
re an expert must check the
fi
replace
and the chimney in order to ensure that it is fully functional.
•
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a
fi
replace.
See
“2.0 Technical Data”
for speci
fi
ed weight.
We recommend the removal of any
fl
ooring that is not attached
to the foundation (“
fl
oating
fl
oors”) beneath the installation.
Requirements for protection of wooden
fl
ooring beneath the
fi
replace
The product can be placed directly on a wooden
fl
oor,
protected by a
fl
oor plate made from non combustible material
(recommended thickness - minimum 0,9 mm)
Jøtul recommends that any
fl
ooring made of combustible
material, such as linoleum, carpets, etc. should be removed
from under the
fl
oor plate.
Requirements for protection of
in
fl
ammable
fl
oors under the
fi
replace
The
fl
oorplate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions
and installation requirements.
3.3 Walls
• The product should be placed so that it is possible to clean
the stove,
fl
ue pipe and chimney outlet.
• Make sure furniture and other combustible materials do not
get too close to the stove.
• Make shure furniture and other items are not placed too
close to the stove, to prevent them from drying out.
Distance to wall of combustible material - see
fi
g. 1. The
distance is with a shielded
fl
ue / semi-insulated pipe.
The
fi
replace can be installed with uninsulated
fl
ue. Then the
fl
ue must be CE marked and the declared distance of the pipe
to combustible must be maintained.
Combustible wall protected by
fi
rewall
Distance to combustible wall protected by
fi
rewall: See
fi
g. 1
. Distances with semi-inslulated chimney/shielded
fl
ue pipe
are shown in
fi
g. 1.
Firewall requirement
The
fi
rewall must be at least
100 mm
thick and be made of
brick, concrete-stone or light concrete. Other materials and
structures with satisfactory documentation may also be used.
Non-combustible materials mean materials like brick, clinker,
concrete, mineral wool, cilicate plates etc (materials that do
not burn).
Note!
A short distance to non-combustible wall
may lead to desiccation and discoloration of paint and cause
cracking.
3.4 Ceiling
There must be a minimum distance of
750 mm
to a combustible
ceiling above the
fi
replace.