Jøtul C 24 IT Installation And Operating Instructions Manual Download Page 6

6

3.0 Safety 

NB! To guarantee optimal performance and safety, Jøtul 
stoves must be 

fi

 tted by a quali

fi

 ed installer.

Any modi

fi

 cations to the product by the distributor, installer or 

consumer may result in the product and safety features not 
functioning as intended. The same applies to the installation of 
accessories or optional extras not supplied by Jøtul. This may 
also be the case if parts that are essential to the functioning and 
safety of the 

fi

 replace have been disassembled or removed.

In all these cases, the manufacturer is not responsible or liable 
for the product and the right to make a complaint becomes null 
and void.

Keep the door closed during use (the product is not approved 
for use with open door

3.1 Fire Prevention Measures

There is a certain element of danger every time you use 
your 

fi

 replace. The following instructions must therefore be 

followed: 
•  The minimum safety distances when installing and using 

the 

fi

 replace are given in 

fi

 g. 1A

 and 

fi

 g. 1B

.

•  Ensure that furniture and other 

fl

 ammable  materials  are 

not too close to the 

fi

 replace. Flammable materials should 

not be placed within 1,05 metre of the 

fi

 replace.

• Allow 

the 

fi

 re to burn out. Never extinguish the 

fl

 ames with 

water.

• The 

fi

 replace becomes hot when lit and may cause burns 

if touched.

•  Only remove ash when the 

fi

 replace is cold. Ash can 

contain hot embers and should therefore be placed in a 
non-

fl

 ammable container.

•  Ash should be placed outdoors or be emptied in a place 

where it will not present a potential 

fi

 re hazard.

In case of chimney 

fi

 re: 

•  Close all hatches and vents.
• Keep 

the 

fi

 rebox door closed.

•  Check the loft and cellar for smoke.
• Call 

the 

fi

 re service.

Before use after a 

fi

 re an expert must check the 

fi

 replace and 

the chimney in order to ensure that it is fully functional

.

4.0 Installation 

The 

fi

 replace surround must have a minimum opening of HxWxD 

= 515x715x490 mm. It is also important to allow space for 
insulation around the surround. If using a wide frame (optional 
extra), it will overlap openings to HxW = 558x755 mm.
A narrow frame is included with the product. It is possible to 
move this frame and a wide frame (optional extra) up to 40 
mm to make it easier to adapt the product for di

 erent 

fl

 ue 

pipe positions.

4.1 Floor

Foundation

You need to make sure the foundation is suitable for a 

fi

 replace. 

See 

“2.0 Technical Data”

 for speci

fi

 ed weight. 

Requirements for protection of wooden 

fl

 ooring beneath the 

fi

 replace

The Jøtul C24 has a heat shield underneath to protect the 

fl

 oor 

from radiated heat. The product can therefore be positioned 
directly on a wooden 

fl

 oor that is covered by a sheet of metal 

or other non-in

fl

 ammable material. The recommended minimum 

thickness is 

0.9 mm

. The plate must cover the entire 

fl

 oor 

surface within the surround. 

We recommend the removal of any 

fl

 ooring that is not attached 

to the foundation (“

fl

 oating 

fl

 oors”) beneath the installation. 

Any 

fl

 oor covering of in

fl

 ammable material, such as linoleum, 

carpets, etc. must be removed from under the 

fl

 oor plate. 

Requirements for protection of in

fl

 ammable 

fl

 oors in front of the 

fi

 replace

The 

fl

 oor in front of the 

fi

 replace must be protected by a sheet 

of metal or other non-in

fl

 ammable material. The recommended 

minimum thickness is 0.9 mm. The 

fl

 oor plate must comply with 

national laws and regulations. 
Contact your local building authorities regarding restrictions and 
installation requirements. 

4.2 Ceiling

Distance from hot air vents in the top

 ( Fig. 1B-V 

or 500 mm).

ENGLISH

Summary of Contents for C 24 IT

Page 1: ...ructions 2 IT Manuale di installazione ed uso 18 J tul C 24 IT Manual Version P02 I manuali inclusi con il prodotto vanno conservati per l intera durata di vita del prodotto Sostituire le Istruzioni d...

Page 2: ...itute Approved by Minimum distance to adjacent combustible materials OGC SP EN Lot no Pin 1 0 Regulatory information Installation of a fireplace must be according to local codes and regulations in eac...

Page 3: ...3 J tul C 24 IT inclusive optional wide frame Fig 1A 900167 P01 ENGLISH...

Page 4: ...4 J tul C24 IT inclusive optional narrow frame Fig 1B 900167 P01 ENGLISH...

Page 5: ...5 Fig 2 900167 P01 ENGLISH...

Page 6: ...Call the fire service Before use after a fire an expert must check the fireplace and the chimney in order to ensure that it is fully functional 4 0 Installation The fireplace surround must have a min...

Page 7: ...outside air Ducts in the room where the stove is installed must be made of a non combustible material such as a flexible aluminium pipe with an internal diameter of 80 or 100 mm A fresh air duct conn...

Page 8: ...han 45 must be fitted with a sweeping hatch Note that it is possible to sweep from the inside of the burn chamber See Chapter 7 2 NB A correct and airtight connection is extremely important for the fu...

Page 9: ...e 4 screws Fig 7A holding the door lock and hinges in place Scrape any traces of glue o the surfaces Fig 7C Fig 8 180 180 180 6 Rotate the parts of the door lock axis by 180 Fig 9 A 7 Install the door...

Page 10: ...ou have help when positioning and installing it 1 Position the product in the surround so that the front part of the product and the front part of the surround are aligned Fig 11 A A 2 Unscrew the 4 s...

Page 11: ...vent Fig 14B can be pulled forward This makes it easier to reach Next tighten the nuts 6 If everything looks right put the 4 screws Fig 101A that were removed back into place 7 Secure the frame into p...

Page 12: ...Place the flue pipe in the flue outlet of the heat exchanger fig 16 C 4 12 Performance check Once the product has been assembled always check the control handles These should move easily and work in a...

Page 13: ...usting the air vent Fig 18A Check that afterburning secondary combustion starts This is best indicated by yellow flames in front of the holes under the ba e Fig 18C If the chimney draught is normal th...

Page 14: ...finely split wood Length 20 30 cm Diameter 2 5 cm Quantity for kindling 6 8 pieces Wood split wood Recommended length 30 50 cm Diameter Approx 8 cm Stoking frequency Approx every 45 minutes Fire size...

Page 15: ...e product are illegal Only original spare parts may be used 6 1 Replacing the burn plates Fig 20 A B A Fig 21 A 10mm B 1 Remove the side burn plates by lifting them slightly and pulling out at the bot...

Page 16: ...a good idea to do this when cleaning the chimney and flue pipes 7 2 Sweeping the flue pipe to the chimney Flue pipes must be swept through the flue pipe sweeping hatch or through the door opening The...

Page 17: ...fireplace The buyer is entitled to return the goods provided that the fireplace has been installed in compliance with current laws and regulations and in compliance with J tul s installation and oper...

Page 18: ...Nm3 Temperatura dei fumi 213 C Funzionamento intermittente Per funzionamento intermittente si intende il normale utilizzo di un caminetto Ci significa che per riattizzare il fuoco necessario aggiunger...

Page 19: ...umi Misure di installazione min Pavimento apertura nel rivestimento utilizzando un telaio ampio opzionale montanti regolabili fino a 20 mm distanza minima dal pavimento non ignifugo telaio regolabile...

Page 20: ...distanza minima dal pavimento non ignifugo III telaio regolabile di 40 mm Prodotto Pavimento Misure della piastra di protezione del pavimento X Y in conformit con le norme e i regolamenti nazionali P...

Page 21: ...o Vedere capitolo 4 3 II utilizzare una piastra d acciaio sotto all isolamento se necessario III Distanza dai mobili combustibile I Muro tagliafuoco J tul JGFW 5 50 mm di spessore Canna fumaria isolat...

Page 22: ...so tta Chiamare i vigili del fuoco Prima di utilizzare di nuovo il camino e la canna fumaria dopo un incendio necessario che vengono controllati da un tecnico specializzato che ne assicuri l integrit...

Page 23: ...ultare il pi lineare possibile I condotti della stanza in cui viene installata la stufa devono essere realizzati in materiale ignifugo come un tubo di alluminio flessibile con un diametro interno di 8...

Page 24: ...are un condotto provvisto di portello che consenta di e ettuarne la pulizia necessario installare un gomito dei fumi di scarico che modifichi la direzione dei fumi di scarico di oltre 45 con un portel...

Page 25: ...180 o 4 Rimuovere il gruppo del fermo sulla parte destra del prodotto e attaccarlo nel punto in cui i cardini si trovavano sul lato sinistro Fig 7 A A A A B C 5 Rimuovere la manopola Fig 7B dal fermo...

Page 26: ...nte la regolazione 4 10 Montaggio installazione Installazione Il prodotto pesante Assicurarsi di disporre dell aiuto necessario in fase di posizionamento e installazione 1 Posizionare il prodotto nel...

Page 27: ...imaria Fig 14B Ci ne facilita il raggiungimento Successivamente serrare i dadi 6 Se tutto sembra corretto reinserire in posizione le 4 viti Fig 11 A precedentemente rimosse 7 Fissare in posizione il t...

Page 28: ...chiusa Posizione destra completamente aperta Presa di accensione Fig 18B Posizione sinistra chiusa Posizione destra completamente aperta Fig 16 A B C 10 Posizionare la guarnizione sullo scambiatore F...

Page 29: ...Ci viene indicato dalla presenza di fiamme gialle e guizzanti davanti ai fori sotto il parafiamma Fig 18C Se il flusso d aria normale il fuoco si regoler autonomamente Importante Una circolazione del...

Page 30: ...quando l apertura della presa d aria pari al 50 circa 5 2 Eliminazione della cenere Rimuovere la cenere solo con il caminetto freddo 5 3 Accensione in primavera e autunno In primavera e autunno quand...

Page 31: ...steriore devono essere sostituite se danneggiate 3 Per l installazione seguire la stessa procedura in ordine inverso ITALIANO 6 2 Sostituzione del parafiamma deflettore di aspirazione Fig 22 A 1 Per p...

Page 32: ...scambiatore Per pulire lo scambiatore rimuovere i laterali della camera di combustion il deflettore inferior e quello superior vedere capoitolo 6 2 Mettersi dei guanti di protezione e pulire con una s...

Page 33: ...L acquirente ha diritto alla restituzione delle merci nel caso in cui il caminetto sia stato installato in conformit alle leggi e normative vigenti e in conformit alle istruzioni di installazione e fu...

Page 34: ...34...

Page 35: ...aminated by external stove cement or glue 9 Produktet har ingen sprekker i glass st pejern eller andre deler There are no cracks in glass cast iron or other parts 9 Pakninger er riktig lagt og skjemme...

Page 36: ...vikling produksjon og salg av ildsteder V r kvalitetspolitikk skal gi kundene den trygghet og kvalitetsopplevelse som J tul har st tt for siden bedriftens historie startet i 1853 Qualit J tul AS adott...

Reviews: