background image

Denmark

Kelvin Hughes A/S
Århus
Tel        +45 861 12888
Fax       +45 861 12726
[email protected]

Denmark

Maritek Marine Electronics
Strandby Vends.
Tel        +45 984 81250
Fax       +45 984 82066
[email protected]

Denmark

Lindpro A/S
Esbjerg
Tel        +45 751 23455
Fax       +45 751 38408
[email protected]

Denmark

Navicom Marine
Svenstrup
Tel        +45 983 80047
Fax       +45 983 80047
[email protected]

Denmark

Pentagon Electric
Hjortshøj
Tel        +45 862 23053
Fax       +45 862 29229
[email protected]

Denmark

Semco Callenberg Marine A/S
Odense S
Tel        +45 702 63501
Fax       +45 702 63502
[email protected]

Denmark

Stella Marine
Frederiksværk
Tel        +45 47761213
Fax       +45 47761215
[email protected]

Egypt

*Radio Holland Eqypt S.A.E.
Alexandria
Tel        +20 3 4806899
Fax       +20 3 4804196
[email protected]

Egypt

Radio Holland Eqypt S.A.E.
Port Said
Tel        +20 66 323801
Fax       +20 66 228644

Egypt

Radio Holland Eqypt S.A.E.
Suez
Tel        +20 62 341474
Fax       +20 62 320139

Equador

*VG Electronica
Guayaquil
Tel        +593 4 231 0855
Fax       +593 4 231 0850
[email protected]
www.vgelectronica.com

Estonia

*AS RSTA
Tallinn
Tel        +372 6 605850
Fax       +372 6605715
[email protected]
www.rsta.com

Faroe Islands

Gummibådstjenesten
Torshavn
Tel        + 298 314913
Fax       + 298 310656
[email protected]

Finland

*AT-Marine Oy
Vantaa
Tel        +358 9 54942600
Fax       +358 9 54942700
[email protected]
www.atmarine.fi

France

Electronic Equipment  (Main office)
Montivilliers
Tel        +33 2 32 79 29 60
Fax       +33 2 35 20 82 75

France

Electronic Equipment
Marseille
Tel        +33 49 1699024
Fax       +33 49 1699112

France

Martec
Sevres
Tel        +33 14 6237126
Fax       +33 14 6237157
[email protected]
www.martec.fr

Germany

*Nera GmbH
Hamburg
Tel        +49 40 682770
Fax       +49 40 68 277 135
[email protected]
www.nera.de

Germany

Lammers Schiffselektronik GmbH
Leer
Tel        +49 491 66500
Fax       +49 491 66831
[email protected]

Germany

Pro Nautas
Leer
Tel        +49 491 987900
Fax       +49 491 9879029
[email protected]

Germany

Telcom Electronics Trade GmbH
Hamburg
Tel        +49 40 656 8960
Fax       +49 40 656 89777
[email protected]
www.TELCOM-Germany.de

Germany

Ing.-Büro Querin GmbH
Dollern
Tel        +49 4163 811631
Fax       +49 4163 811633
www.querin-shipsupply.com

Gibraltar

Sandvik Marine Group
New Harbour
Tel        +350 79003
Fax       +350 46419
[email protected]
www.sandvikmarine.com

Greece

*ELINE-A.J.Karageorgis Marine
Hellinico
Tel        +30 210 96 46 174/75
Fax       +30 210 96 46 178
[email protected]
www.eline.com.gr

Greece

*Radio Holland Greece
Piraeus
Tel        +30 210 411 02 60
Fax       +30 210 417 77 84
[email protected]
www.srhmar.com

Greece

Fastnet Radio Ltd
Nea Smyrni - Athens
Tel        +30 210 9356516
Fax       +30 210 9357088
[email protected]

Greece

Hellenic Radio Services S.A.
Piraeus
Tel        +30 210 41 81 218
Fax       +30 210 42 82 883
[email protected]

Greenland

Brand-og redningsmateriel
Godthåb
Tel        +299 349988
Fax       +299 320438
[email protected]
www.securitas.gl

Greenland

O.S. Electronik
Nuuk
Tel        +299 23536
Fax       +299 22779
[email protected]

Hong Kong

*Radio Holland Hong Kong Co. Ltd.
Kwai Chung, NT
Tel        +852 2423 9007
Fax       +852 2480 5898
[email protected]
www.radiohollandhongkong.com

Iceland

*Radiomidun Ltd.
Reykjavik
Tel        +354 511 1010
Fax       +354 511 1020
[email protected]
www.radiomidun.is

India

*Elektronik Lab
Mumbai
Tel        +91 22 24715115
Fax       +91 22 24710444
[email protected]

India

Elektronik Lab
Chennai (Madras)
Tel        +91 44 24342839
Fax       +91 44 24325264
[email protected]

24

Summary of Contents for Tron VHF

Page 1: ...Tron VHF your safety our concern GB OPERATORS MANUAL www los grafisk no O nr 250854...

Page 2: ...nts have the necessary equipment and education to test the operational functions of the beacon Non original maintenance and or service parts may destroy the equipment function and performance The info...

Page 3: ...3 CHANGES RECORD NO CHAPTER VERSION NEW MANUAL EM3903 CAP 5 B REVISION HISTORY...

Page 4: ...the battery 16 3 2When to change the battery 16 3 3 Special Care 17 4 SECONDARY BATTERYAND CHARGER 17 4 1 Using the Nickel Cadmium battery 17 4 2 How to charge the Nickel Cadmium battery 17 4 3 Specia...

Page 5: ...ch ofVessels in Distress S A R S A T Search and Rescue Satellite AidedTracking System EPIRB Emergency Position Indicating Radio Beacon LUT Local UserTerminal Ground Station MCC Mission Control Center...

Page 6: ...E A S U R E S In case of contact of cell contents with eyes flush immediately with water for 15 min With skin wash with plenty of water and take off contaminated clothes If inhalation remove from exp...

Page 7: ...D I O E Q U I P M E N T A N D R E S E RV E S O U R C E O F E N E R G Y Weekly GMDSS handheld VHF transceivers to be tested without using the mandatory required emergency batteries Monthly Float free...

Page 8: ...8...

Page 9: ...9 DATE N T B SIGN INSP N NEW EPIRB INSTALLED T TEST B NEW BATTERY TEST AND MAINTENANCE RECORD...

Page 10: ...ating channels for international maritime mobile service and is well fitted for on board communication 1 2 F E AT U R E S Watertight TronVHF is watertight to a depth of 1 metre for 5 minutes With the...

Page 11: ...TronVHF is built with a frequency synthesizer to assure an easy channel selec tion with high frequency stability Electronic construction TronVHF is built with surface mount techniques on one multilaye...

Page 12: ...active when there is light under the channel number If channel 16 is active turning the rotary switch will activate rotary channel selector and turn of channel 16 4 ON Channel 16 selector Pushing ON 1...

Page 13: ...is increased with increasing number in indication window 13 Remote connector Connector for remote equipment See section A 2 3 for pin description 14 Channel 16 indication Light is indicating that cha...

Page 14: ...careful not to turn the squelch level to high This may lead to no squelch opening when weak signals are received TheTronVHF is now ready for reception 5 Selecting another channel is done with the CH...

Page 15: ...tion on the mobile station being at distress information on position what kind of emergency it is what kind of help is needed other information that can be of any help to the rescue operation 4 Emerge...

Page 16: ...seal to prevent inadvertent use Break this seal before use Breaking this seal indicates that the shelf life has expired 4 Push the new battery unit into the housing until you hear the two push button...

Page 17: ...e used in the same way as the primary battery unit However the voltage of Nickel Cadmium batteries drops rapidly just before they are exhausted so when the transmit indicator LED Tx goes out be sure t...

Page 18: ...mode This is indicated with the Charge LED switching off There are also built in temperature sensors detecting charge temperature limits and sudden rises in battery temperature If the charger is detec...

Page 19: ...o follow JOTRON s instructions with respect to approved service agents or if the unit has been exposed to environmental conditions outside the specifications for the unit As a standard Jotron Electron...

Page 20: ...N agent 1 Battery IfTx light is flashing change the battery Also check ifTx light is flashing during transmitting 2 Volume control Check ifVOL control is smooth operating and check if sound is increas...

Page 21: ...nnel is selected try another channel b Try a reset by switching power OFF c Test EEPROM for channel data An JOTRON agent can do this If this doesn t help check synthesizer Transmitter must be checked...

Page 22: ...th orange top Makes the unit floating 93003 Rechargeable NiCad battery 850 mAh Black colour Makes the unit non floating 93080 Tron Charge battery charger 220V AC as standard 93031 Leather carrier case...

Page 23: ...avcom Marine Inc Montreal Tel 1 450 466 6638 Fax 1 450 466 8829 Canada Scantech Inc Qu bec Tel 1 472 653 1772 Fax 1 418 652 1258 Canada Ship s Electronic Services Nova Scotia Tel 1 902 861 3022 Fax 1...

Page 24: ...7157 marine martec fr www martec fr Germany Nera GmbH Hamburg Tel 49 40 682770 Fax 49 40 68 277 135 Nera HH nera no www nera de Germany Lammers Schiffselektronik GmbH Leer Tel 49 491 66500 Fax 49 491...

Page 25: ...972 4 8627404 m_yules alhoutyam co il Japan Kaigai Gijyutsu K K Yokohama Tel 81 45 664 7318 Fax 81 45 664 7320 cs kgkjp com Japan Kaigai Gijyutsu K K Kobe Tel 81 78 331 2705 Fax 81 78 331 2703 kgkkobe...

Page 26: ...AS Skien Tel 47 35 90 04 00 Fax 47 35 52 24 35 postmaster basse gundersen no Norway J M Hansen A S Troms Tel 47 77 66 55 00 Fax 47 77 66 43 81 tromso navy no Norway Harstad Elektronikk AS Harstad Tel...

Page 27: ...780 hitek sinfo net Panama Servitronic S A Panam Tel 507 261 9703 Fax 507 261 9800 aabreu sinfo net Philippines Delnet International Intramuros Manila Tel 63 2 522 3947 Fax 63 2 527 6019 delnet pldtds...

Page 28: ...a Primorsk Shipping Corporation Nakhodka Tel 7 4266 42504 Fax 7 4266 94552 klishin prisco ru Russia Sudoremkomplekt Kamchatka Tel 7 4266 42504 Fax 7 4266 94552 klishin prisco ru Russia The Astrakhan C...

Page 29: ...rhme ae United Arab Emirates Saab Marine Middle East Sharjah Tel 971 6 557 0740 Fax 971 6 557 0741 saabme emirates net ae www saab tankradar com United Kingdom Jotron UK Ltd Cramlington Northumberlan...

Page 30: ...34 8535 nola mackaymarine com www radiohollandusa com United States Mackay Marine Miami FL Tel 1 305 591 3399 Fax 1 305 591 1879 miami mackaycomm com www radiohollandusa com United States Mackay Marin...

Page 31: ......

Page 32: ...JOTRON Electronics a s P O Box 54 NO 3280 Tjodalyng Norway Tel 47 33 13 97 00 Fax 47 33 12 67 80 www jotron com www los grafisk no O nr 250854...

Reviews: