7
5.5 CONTROL
Mount the GI-2000 controller conduit port on the GI-2000. The control
wiring conduit port is the round connector near the top of the GRD (See
Diagram A)
.
Connect the controller cable to the control wiring conduit port.
Should additional length be required use Beldon type 8469 (9 Conductor
Cable). DO NOT exceed 200’.
5.6 RECLAIM
TANK
The GI-2000 is shipped with a ¾” NPT brass outlet fitting. The fitting if
removed is a ¾” M.I.P. fitting. Maximum head is 15’ (maintain ¾”
connection). Appropriate material should be used to accommodate
possible temperatures of 140°F, as well as vibrations, when pumping.
When applications warrant a distance between the GI-2000 and the
reclaim tank, the piping must be sloped toward the reclaim tank. Heat
tracing may also be required.
Venting is required
.
5.7
RECLAIM TANK ALARM
A reclaim tank alarm is suggested and available as an optional feature
(See Diagram C). Contact Josam Company or your local Josam
representative for additional pumping requirements and available options.