With the appliance operating, turn the gas cylinder off, ‘Close’. The 
burner will continue to operate until all gas has been bled from 
the gas hose and regulator assembly. 

1.

 

Turn off the water supply at the tap (mains) and disconnect 
from the ‘Water Input’. Disconnect the shower hose from 
the ‘Water Output’. Allow all water to drain out from hosing 
before rolling up and storing away. 

2.

 

Disconnect the gas regulator and hose assembly from the appliance and gas cylinder and store 
away. To do this, first:   

2.1

 

Check that the appliance is fully extinguished; the gas cylinder control valve is in 
the fully off, ‘Close’, position and all surfaces are cool. 

2.2

 

Loosen the connection to the gas cylinder in a clockwise direction and remove. 

2.3

 

Using a spanner, loosen the connection to the gas inlet in an anti-clockwise 
direction and remove. 

 

3.

 

Disconnect the quick connect adaptors from the ‘Water Input’ and ‘Water Output’. 

4.

 

To ensure that the water has completely drained from the appliance, open the drain valve 
(ribbed cylindrical stem next to the ‘Water Input’). Make sure to close the drain valve once 
water has been drained. 

Using warm, soapy water and a mild detergent wipe down all 
surfaces and areas of the appliance. Take care not to allow water 
to enter the top vent.

   

 

Before each use, check that the screen filter on the ‘Water Input’ 
pipe is in place and cleaned of any particles.  

   

DO NOT

 submerge the appliance in a sink or bowl.   

   

DO NOT

 use abrasive cleaners or bleach.   

   

 

 

5

 

1

 

Storage 

Care Instructions 

Summary of Contents for JCA11001

Page 1: ...ions carefully and understand the operation and safety features of this appliance Familiarise yourself with the appliance before connecting it to the gas container Failure to follow the warnings and i...

Page 2: ...DESIGNED TO BE USED WITH A SOURCE WATER TEMPERATURE OF 20 C OR BELOW IF THE TEMPERATURE OF THE OUTLET WATER EXCEEDS 50 C THE BURNERS WILL SHUT OFF YOU WILL BE REQUIRED TO TURN THE WATER FLOW OFF AND...

Page 3: ...m Dimensions 370H x 275W x 165Dmm Weight 4 3kg Approval Number GMK10121 Run Time from 9kg Bottle 15hrs Battery 2 x DD for ignition only Flow Rate 4L 6L Per Minute Max Temp 50 C Max Temp Rise 35 C Min...

Page 4: ...S ONLY IT MAY BE HAZARDOUS TO ATTEMPT TO FIT OTHER TYPES OF GAS CONTAINERS This appliance shall only be used in an above ground open air situation with natural ventilation without stagnant areas where...

Page 5: ...n the cylinder disconnect from the appliance and hold the cylinder in a vertical position then shake from side to side if there is a sound or feel of liquid movement inside the cylinder contains gas W...

Page 6: ...temperature reaches 50 C To relight the burner you will need to turn the water flow off and back on Water flow sensor Water must be flowing through the system to allow the burner to ignite In the case...

Page 7: ...fittings to the Water Input and Water Output threads respectively 3 To connect the showerhead to the shower hose place one of the washers contained in the pack into one end of the threaded fitting of...

Page 8: ...nnect the flexible gas hose to the gas inlet Tighten the connection with a spanner taking care not to over tighten as doing so may damage the assembly 3 Connect the gas regulator to the POL propane ga...

Page 9: ...nozzle is in the Off position 6 When ready slide the flow regulation switch on the shower nozzle to the On position Water will start to flow 7 Adjust the temperature and flow rate through the shower...

Page 10: ...l surfaces are cool 2 2 Loosen the connection to the gas cylinder in a clockwise direction and remove 2 3 Using a spanner loosen the connection to the gas inlet in an anti clockwise direction and remo...

Page 11: ...sure and at least 4LPM to activate the burners There is the possibility of finding some kind of epoxy or debris within the water regulator Check that the water inlet filter screen is clean To flush th...

Page 12: ...temperature To increase temperature turn the gas regulator control from minimum to maximum and turn the water regulator control from maximum to minimum Check source water temperature If the source wa...

Page 13: ...at least 4LPM to activate the burners Ensure that the Liquid Propane regulator is correctly threaded to the unit and that there is an adequate amount of gas in the Propane bottle Verify that the incom...

Reviews: