JS-3 Jet Sustainer
Flight Manual Supplement
JS03-AFM-00-002
Issue: 00.32JS
Rev. 00.32JS
Rev. Date: 08.02.2019
Page 3
–5
Electrical fire
3.3.3
An electrical fire is very unlikely due to the protection with circuit
breakers for all systems. Each battery has a circuit-breaker at the
terminals and each battery device has a circuit breaker switch on the
instrument panel.
In the event of smoke or fumes coming from the instrument panel, take
the following action:
1. Switch off the master switch supplying the circuits.
2.
If a circuit breaker “pops”, reset once only. This is most probably
the faulty circuit.
3. Land as soon as possible.
4. Ensure the aircraft is serviceable before commencing with further
flying.
Electrical failure
3.3.4
If an electrical failure occurs or the batteries supplying the Jet System
being fully discharge with the engine extended, the engine cannot be
retracted.
The pilot may continue the flight with the engine extended, provided the
maximum speed is limited to V
PE
.