Errors during Running
5.2.2
The following lists the error messages that may occur during the RUN
state:
Overheat
Flameout
No RPM
Pump Overcurrent
5.2.2.1
Overheat
Error Description:
Measured EGT exceeded 850 °C (1562 °F).
Possible Causes:
Defective engine
Engine fire
Defective RPM sensor causing an engine over-speed
Incorrect EGT measured
Pilot action required:
Close fuel valve
Toggle Jet Control toggle switch to Extend.
Only retract engine when temperatures stabilised below 55 °C
(131 °F).
Ground maintenance actions are required