background image

MADE IN ITALY

JO

NIX

maxima

te

AIR PURIFICATION DEVICE

WITH ADVANCED COLD PLASMA TECHNOLOGY

USE AND MAINTENANCE MANUAL

Summary of Contents for maximate

Page 1: ...MADE IN ITALY JONIX maximate AIR PURIFICATION DEVICE WITH ADVANCED COLD PLASMA TECHNOLOGY USE AND MAINTENANCE MANUAL...

Page 2: ...IX S p A reserves every right concerning this manual including the right to make any necessary change or improvement to its products and to the manual at any time and without notice It is forbidden to...

Page 3: ...OPERATING CONDITIONS 10 6 INSTALLATION AND COMMISSIONING 11 6 1 SAFETY STANDARDS 11 6 2 GETTING STARTED 12 6 3 CHOOSING THE INSTALLATION SITE 13 6 4 ELECTRICAL CONNECTIONS 13 6 5 ELECTRIC POWER SUPPLY...

Page 4: ...filtering module Improper installation of the device and or failure to comply with the instructions in this manual may invalidate the warranty that the Manufacturer issues for its products The Manufa...

Page 5: ...ce is designed and made to sanitise the air in residential environments that are incompatible with toxic and flammable gases It is therefore strictly forbidden to use the device in environments where...

Page 6: ...pany that sold you the device 2 WARNINGS AND GENERAL PROHIBITIONS HAZARD It refers to dangerous situations that may result from the use of the device in order to ensure personal safety WARNING It refe...

Page 7: ...of the device Please note that the use of products that require electricity involves the observance of some crucial safety rules such as When installing commissioning and operating this product it is...

Page 8: ...s Aureus Abatement 98 Aspergillus Niger Abatement 96 Saccharomyces Cerevisiae Abatement 99 neutral molecule O2 CO2 H2 O gas molecule O2 O3 NO NO2 stable negative ion O O2 O3 The JONIX maximate mobile...

Page 9: ...13 09 Straight plug 04 Main filter H13 HEPA filter Class EN 1822 ISO 29463 10 Swivel casters with brake 05 Plug centrifugal EC fan n 2 11 Straight connector 06 Secondary filter F7 Fine dust filter Cl...

Page 10: ...anual Declaration of Conformity Warranty conditions 5 1 PACKAGING Any type of complaint must be sent in writing within eight days from receiving the goods When you receive the device please check all...

Page 11: ...products used for cleaning and servicing the device you should also observe the recommendations given by the manufacturer of such products Before switching the device on check the integrity of the var...

Page 12: ...ce work on the device except where specified in this manual Opening or removing the outer casing may expose you to dangerous live parts or may involve other risks All maintenance work must be carried...

Page 13: ...e electrical connections must be carried out following the instructions provided in this manual Make sure that voltage and frequency of the electric line correspond to those provided on the name plate...

Page 14: ...ule is ready to work In order to turn on the device act on the selector positioned on the panel turning it to I 6 6 USING THE DEVICE The control and the setting of functions is set using the Display s...

Page 15: ...show the wear status of the ionisers left or right When the cleaning of the ionizing tubes will be needed or once the bars will be filled to indicate that the ionizing tube has to be replaced an alarm...

Page 16: ...r intervention is needed this alert state will be shown with the appearance of a notification on the icon of the device part that has caused the alarm Touching the alarm notification the user will be...

Page 17: ...dule c Maintenance menu quick key to access the module maintenance screen and record the maintenance operation performed 6 8 3 Filters screen replacement becomes necessary ATTENTION this number could...

Page 18: ...s summary Measured air flow m3 h it is the real time measurement of the air flow of the fan from the appropriate sensor Pressure drop Pa it is the real time measurement of the pressure drop on the fan...

Page 19: ...otected with password are Device On Off Ionising modules On Off Increase decrease of the fan speed The screens that are protected with password regardless the protection level set are Protection Time...

Page 20: ...each day of the week it is possible to set up to 4 time slots When time slots are enabled it is not possible change the operating status of the ionising modules or the air flow rate of the fan in thei...

Page 21: ...f the components but only the recording of the system of the intervention carried out by the user The maintenance procedures are explained in the chapter Maintenance of this manual Ionisers Maintenanc...

Page 22: ...ned in the chapter Maintenance of this manual Filters Maintenance Maintenance operations on the corresponding filter can be recorded in the system from this menu a Filter H13 b Filter F7 c Filter G4 A...

Page 23: ...splay b Video allows to view video contents NOTE if multimedia content is not present the icons are obscured User manual Enables to display an extract of the user manual directly from the display a Ke...

Page 24: ...als the need of maintenance of the modules through an alarm viewed on the display every 7000 hours of operation Filters do not need to be cleaned periodically but will need to be changed when they rea...

Page 25: ...g the Ionising Tubes Fig 05 Gently unscrew the tubes using the green plastic base If you have trouble first pull off the outer mesh Clean the ionising tubes every time it is shown on the display Fig 0...

Page 26: ...sing tube needs replacing The tubes must usually be replaced within 18 months of use Fig 08 Wash the mesh under running hot water and dry it thoroughly with a cloth Fig 09 Put the outer metal mesh bac...

Page 27: ...urface of the tube Check that the earthing spring is in contact with the outer mesh once the ionising tubes have been screwed back into place Otherwise contact the manufacturer Fig 12 Refit the top pa...

Page 28: ...ponents of the device subject to time deterioration hence they need to be replaced are ionising tubes when signs of wear appear it is necessary to replace the component They are evident with the appea...

Page 29: ...Open with the handle the front doors Remove the top panel to access the ionising tubes Fig 15 Gently unscrew the tubes using the green plastic base If you have trouble first pull off the outer mesh Fi...

Page 30: ...s end stop Fig 18 If the operation is difficult to perform pull slightly the earthing spring so that it is not in contact with the surface of the tube Check that the earthing spring is in contact with...

Page 31: ...unplug the device from the mains and contact qualified staff Failure to clean the ionising tubes when indicated by the device leads to a drop in system performance Register the maintenance operation d...

Page 32: ...e plug connected to the mains Fig 22 Open with the handle the front doors Remove the top panel to access the filters Fig 20 Type of filters on the JONIX maximate device a Absolute filter H13 b Thin pa...

Page 33: ...filter locking tabs out Extract the filters Put the new clean filters back in place Push the filter locking tabs towards the device until they click Fig 26 Pull the filter locking tabs out Extract th...

Page 34: ...with the handle the front doors remove the lower panel to access the filters Fig 29 Unscrew the locking knobs and remove the filter locking bracket Extract the filters Put the new clean filters back...

Page 35: ...Register the maintenance operation done using the display Reset the alarm launched by the device in the alarm screen Fig 30 Refit the lower panel Turn on the unit by acting on the disconnector On Off...

Page 36: ...stem detects the need of replacing the tubes for the ionising module The tubes in the ionising module related to the alarm must be replaced Follow the replacement of the ionising tubes procedure in pa...

Page 37: ...ed at special facilities Please inquire through your municipal authorities as to the location of the eco friendly waste management sites where waste can be received for disposal and its subsequent rec...

Page 38: ...38 JONIXmaximate ATTACHMENTS EXPLODED JONIX maximate...

Page 39: ...39 JONIXmaximate 2164 5 205 6 715 715 75 2 1155 75 2 1305 EXPLODED JONIX maximate ambient air ionised air flow...

Page 40: ...40 JONIXmaximate NOTES...

Page 41: ...41 JONIXmaximate...

Page 42: ...42 JONIXmaximate...

Page 43: ......

Page 44: ...ters info jonixair com Certified mail jonixsrl legalmail it web www jonixair com Via Tegulaia 10 b 56121 Pisa Italy tel 39 050 985165 Via dell Artigianato 1 35020 San Pietro Viminario PD Italy Tel 39...

Reviews: